In the paper some case studies of damaged towers in Italy are presented: the Tower Masserano of Palace Ferrero - La Marmora at Biella, the bell tower of the Collegiata of San Vittore at Arcisate, and three medieval towers in Alba. A methodology is put forward for combining laboratory and nondestructive testing methods with monitoring systems in order to reach the goal of evaluating the state of conservation of historic towers and its evolution in time.
A multilevel approach for the damage assessment of Historic masonry towers
ANZANI, ANNA;BINDA, LUIGIA;
2010-01-01
Abstract
In the paper some case studies of damaged towers in Italy are presented: the Tower Masserano of Palace Ferrero - La Marmora at Biella, the bell tower of the Collegiata of San Vittore at Arcisate, and three medieval towers in Alba. A methodology is put forward for combining laboratory and nondestructive testing methods with monitoring systems in order to reach the goal of evaluating the state of conservation of historic towers and its evolution in time.File in questo prodotto: