This paper presents the results of an experimental analysis performed on a microturbine-based small cogenerative plant. The aim of the experimental campaign was to verify behavior and performances of the microturbine at both full and partial load. Attention was particularly paid to the energy saving indexes defined in the AEEG 42/02 Directive (Italian Authority for electrical energy and gas) and EU Directive 2004/8/EC, which is more strict. Such indexes are the energy saving index IRE, the thermal limit LT (AEEG 42/02) and the primary energy saving PES (EU 2004/8/EC). The results of the experimental campaign show that a cogenerative plant equipped with a microturbine as a prime mover can easily exceed the minimum values of the energy saving index imposed by the current directives during operation at full load. On the contrary, very accurate design of the plant and prediction of the load profiles are required to get acceptable results if operation at partial load becomes necessary.

PERFORMANCE ASSESSMENT OF A MICROTURBINE-BASED COGENERATIVE PLANT

COLOMBO, LUIGI PIETRO MARIA;GUILIZZONI, MANFREDO GHERARDO
2010-01-01

Abstract

This paper presents the results of an experimental analysis performed on a microturbine-based small cogenerative plant. The aim of the experimental campaign was to verify behavior and performances of the microturbine at both full and partial load. Attention was particularly paid to the energy saving indexes defined in the AEEG 42/02 Directive (Italian Authority for electrical energy and gas) and EU Directive 2004/8/EC, which is more strict. Such indexes are the energy saving index IRE, the thermal limit LT (AEEG 42/02) and the primary energy saving PES (EU 2004/8/EC). The results of the experimental campaign show that a cogenerative plant equipped with a microturbine as a prime mover can easily exceed the minimum values of the energy saving index imposed by the current directives during operation at full load. On the contrary, very accurate design of the plant and prediction of the load profiles are required to get acceptable results if operation at partial load becomes necessary.
2010
Proceedings of the ASME-ATI-UIT 2010 Conference - Thermal and Environmental Issues in Energy Systems
9788846726599
Cogeneration; Microturbine
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/571060
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact