Heating, ventilation and cooling of buildings are responsible for 30-40% of the energy consumption in buildings and a corresponding significant amount of CO2 emission. Since 2006 the European Energy Performance of Buildings Direc-tive (EPBD) is being implemented in building codes on a national level. Due to high energy consumption and often unacceptable indoor climate energy (noise, draught) some European countries do not recommended full air-conditionings. Alternatively, heating and cooling may be done by radiant heating and cooling systems, where pipes are embedded in the building structure (floors, cei-lings, walls) or in the centre of the concrete slab (Concrete Core Temperature Control). The present paper discuss the limitations and possibilities of radiant cool-ing systems in office buildings demonstrating the essentiality of a good and inte-grated building design to obtain an acceptable comfort level. Different office buildings with different dimensions of south windows are analyzed and their influence of internal comfort are compared.

L'importanza del controllo solare in edifici per uffici con sistemi radianti ad attivazione termica

SALVALAI, GRAZIANO
2009-01-01

Abstract

Heating, ventilation and cooling of buildings are responsible for 30-40% of the energy consumption in buildings and a corresponding significant amount of CO2 emission. Since 2006 the European Energy Performance of Buildings Direc-tive (EPBD) is being implemented in building codes on a national level. Due to high energy consumption and often unacceptable indoor climate energy (noise, draught) some European countries do not recommended full air-conditionings. Alternatively, heating and cooling may be done by radiant heating and cooling systems, where pipes are embedded in the building structure (floors, cei-lings, walls) or in the centre of the concrete slab (Concrete Core Temperature Control). The present paper discuss the limitations and possibilities of radiant cool-ing systems in office buildings demonstrating the essentiality of a good and inte-grated building design to obtain an acceptable comfort level. Different office buildings with different dimensions of south windows are analyzed and their influence of internal comfort are compared.
2009
Sostenibilità e innovazione in edilizia
9788854830394
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/568269
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact