A nove!, non-invasive technique for measuring water content in lungs is described. This technique could find important medicai applications such as rea! time monitoring of lung edema development in patients affected by cardiac insufficiency undergoing physical effort. The technique is based on the moderation (speed decrease) of fast neutrons crossing the lungs, due mostly to the water contained in lungs. In the application of this diagnostic method, the necessary dose given to the patient is lower than that associated with lung imaging techniques that do not use an image ntensifier. The results so far obtained are encouraging, and the method appears to be an improvement over those so far reported in literature as it is able to detect a lung water increase equivalent to 25% of a full edema with a 20% standard error. Research is being performed in order to refine the technique, investigate geometry effects and make the method suitable to the medicai field.

Non-Invasive Measurement of Water Content in Lung Phantom by Neutron

TERRANI, SERGIO;CAMPI, FABRIZIO;
2000-01-01

Abstract

A nove!, non-invasive technique for measuring water content in lungs is described. This technique could find important medicai applications such as rea! time monitoring of lung edema development in patients affected by cardiac insufficiency undergoing physical effort. The technique is based on the moderation (speed decrease) of fast neutrons crossing the lungs, due mostly to the water contained in lungs. In the application of this diagnostic method, the necessary dose given to the patient is lower than that associated with lung imaging techniques that do not use an image ntensifier. The results so far obtained are encouraging, and the method appears to be an improvement over those so far reported in literature as it is able to detect a lung water increase equivalent to 25% of a full edema with a 20% standard error. Research is being performed in order to refine the technique, investigate geometry effects and make the method suitable to the medicai field.
2000
dose assessment, neutrons, diagnostic radiology
File in questo prodotto:
File Dimensione Formato  
campi_terrani_bacelli_2000.pdf

Accesso riservato

Descrizione: ARTICOLO COMPLETO
: Publisher’s version
Dimensione 1.85 MB
Formato Adobe PDF
1.85 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/558989
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 1
social impact