In this paper, an analysis of heart rate variability (HRV) during decreases in the amplitude fluctuations of photopletysmography (PPG) [decreases in the amplitude fluctuations of photopletysmography (DAP)] events for obstructive sleep apnea syndrome (OSAS) screening is presented. Two hundred and sixty-eight selected signal segments around the DAP event were extracted and classified in five groups depending on SaO (2) and respiratory behavior. Four windows around each DAP are defined and temporal evolution of time-frequency HRV parameters was analyzed for OSAS screening. Results show a significant increase in sympathetic activity during DAP events, which is higher in cases associated with apnea. DAP events were classified as apneic or nonapneic using a linear discriminant analysis from the HRV indexes. The ratio of DAP events per hour r(DAP) and the ratio of apneic DAP events per hour r(DAP)(a) were computed. Results show an accuracy of 79% for r(DAP)(a) (12% increase with respect to r(DAP)), a sensitivity of 87.5%, and a specificity of 71.4% when classifying 1-h polysomnographic excerpts. As for clinical subject classification, an accuracy of 80% (improvement of 6.7% ), a sensitivity of 87.5%, and a specificity of 71.4% are reached. These results suggest that the combination of DAP and HRV could be an improved alternative for sleep apnea screening from PPG with the added benefit of its low cost and simplicity.

Discrimination of sleep-apnea-related decreases in the amplitude fluctuations of PPG signal in children by HRV analysis

MENDEZ GARCIA, MARTIN OSVALDO;CERUTTI, SERGIO;BIANCHI, ANNA MARIA;
2009-01-01

Abstract

In this paper, an analysis of heart rate variability (HRV) during decreases in the amplitude fluctuations of photopletysmography (PPG) [decreases in the amplitude fluctuations of photopletysmography (DAP)] events for obstructive sleep apnea syndrome (OSAS) screening is presented. Two hundred and sixty-eight selected signal segments around the DAP event were extracted and classified in five groups depending on SaO (2) and respiratory behavior. Four windows around each DAP are defined and temporal evolution of time-frequency HRV parameters was analyzed for OSAS screening. Results show a significant increase in sympathetic activity during DAP events, which is higher in cases associated with apnea. DAP events were classified as apneic or nonapneic using a linear discriminant analysis from the HRV indexes. The ratio of DAP events per hour r(DAP) and the ratio of apneic DAP events per hour r(DAP)(a) were computed. Results show an accuracy of 79% for r(DAP)(a) (12% increase with respect to r(DAP)), a sensitivity of 87.5%, and a specificity of 71.4% when classifying 1-h polysomnographic excerpts. As for clinical subject classification, an accuracy of 80% (improvement of 6.7% ), a sensitivity of 87.5%, and a specificity of 71.4% are reached. These results suggest that the combination of DAP and HRV could be an improved alternative for sleep apnea screening from PPG with the added benefit of its low cost and simplicity.
2009
time–frequency, Children, decreases in the amplitude fluctuations of photopletysmography (PPG), heart rate variability (HRV), pulse PPG, sleep apnea
File in questo prodotto:
File Dimensione Formato  
Trans_09.pdf

Accesso riservato

: Altro materiale allegato
Dimensione 338.23 kB
Formato Adobe PDF
338.23 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/554836
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 50
social impact