A minidevice for performing gel-free proteome prefractionation via conventional IEF in soluble carrier ampholyte buffers is reported here. It consists of a compact block of polyoxymethylene in which eight samples and two electrode chambers are machined. Each of the eight sample chambers can be filled with up to 120 μL of sample and has the following size: 7 mm width, 3 mm depth and 10 mm height. The anodic and cathodic compartments have the same width and height as the sample chambers, but with a depth of 6 mm, thus accepting up to 250 μL of electrodic solutions. Focusing is in general accomplished in 2 h with a voltage gradient of up to 1000 V (7 cm electrode distance). Easy fractionation and collection of the content of the eight chambers is achieved by simply pressing a rubber diaphragm against the edges of the thin walls separating each well, this automatically breaking liquid continuity. The performance of this device has been tested by subfractionating total cell lysates of a human cancer cell line (U2Os) and of Escherichia coli bacterial cells, and by analysing the content of each chamber by mono-dimensional SDS-PAGE and 2-D maps

Gel-free IEF in a membrane-sealed multicompartment cell for proteome prefractionation.

ANTONIOLI, PAOLO;RIGHETTI, PIERGIORGIO;CITTERIO, ATTILIO;
2007-01-01

Abstract

A minidevice for performing gel-free proteome prefractionation via conventional IEF in soluble carrier ampholyte buffers is reported here. It consists of a compact block of polyoxymethylene in which eight samples and two electrode chambers are machined. Each of the eight sample chambers can be filled with up to 120 μL of sample and has the following size: 7 mm width, 3 mm depth and 10 mm height. The anodic and cathodic compartments have the same width and height as the sample chambers, but with a depth of 6 mm, thus accepting up to 250 μL of electrodic solutions. Focusing is in general accomplished in 2 h with a voltage gradient of up to 1000 V (7 cm electrode distance). Easy fractionation and collection of the content of the eight chambers is achieved by simply pressing a rubber diaphragm against the edges of the thin walls separating each well, this automatically breaking liquid continuity. The performance of this device has been tested by subfractionating total cell lysates of a human cancer cell line (U2Os) and of Escherichia coli bacterial cells, and by analysing the content of each chamber by mono-dimensional SDS-PAGE and 2-D maps
2007
File in questo prodotto:
File Dimensione Formato  
551937.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 401.18 kB
Formato Adobe PDF
401.18 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/551937
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 8
social impact