The effect of accidental drops on MEMS sensors are examined within the framework of a multi-scale finite element approach. With specific reference to a polysiliconMEMS accelerometer supported by a naked die, the analysis is decoupled into macro-scale (at die length-scale) and meso-scale (at MEMS length-scale) simulations, accounting for the very small inertial contribution of the sensor to the overall dynamics of the device. Macro-scale analyses are adopted to get insights into the link between shock waves caused by the impact against a target surface and propagating inside the die, and the displacement/acceleration histories at theMEMS anchor points. Meso-scale analyses are adopted to detect the most stressed details of the sensor and to assess whether the impact can lead to possible localized failures. Numerical results show that the acceleration at sensor anchors cannot be considered an objective indicator for drop severity. Instead, accurate analyses at sensor level are necessary to establish how MEMS can fail because of drops.

Multi-scale analysis of MEMS sensors subject to drop impacts

MARIANI, STEFANO;GHISI, ALDO FRANCESCO;CORIGLIANO, ALBERTO;
2007-01-01

Abstract

The effect of accidental drops on MEMS sensors are examined within the framework of a multi-scale finite element approach. With specific reference to a polysiliconMEMS accelerometer supported by a naked die, the analysis is decoupled into macro-scale (at die length-scale) and meso-scale (at MEMS length-scale) simulations, accounting for the very small inertial contribution of the sensor to the overall dynamics of the device. Macro-scale analyses are adopted to get insights into the link between shock waves caused by the impact against a target surface and propagating inside the die, and the displacement/acceleration histories at theMEMS anchor points. Meso-scale analyses are adopted to detect the most stressed details of the sensor and to assess whether the impact can lead to possible localized failures. Numerical results show that the acceleration at sensor anchors cannot be considered an objective indicator for drop severity. Instead, accurate analyses at sensor level are necessary to establish how MEMS can fail because of drops.
2007
File in questo prodotto:
File Dimensione Formato  
Sensors_2007.pdf

Accesso riservato

: Altro materiale allegato
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/551921
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 57
  • ???jsp.display-item.citation.isi??? 49
social impact