Polymerase Chain Reaction (PCR) plays a central role in the field of molecular biology. The miniaturization of PCR systems is promising as it potentially minimizes costly reagent consumption and time required for analysis. In PCR microdevices a sample solution is usually handled by external pumps. An alternative solution relies on temperature-induced density difference in the presence of a body force to induce buoyancy driven flow. This alternative method is easy to be used and does not require expensive setup, but, to date, the thermo-fluid-dynamic field in the micro-channels still needs to be optimized. The present study focuses on the design of micro-channels, having innovative and optimized shapes to obtain proper fluid actuation and DNA sample amplification within buoyancy driven flow PCR devices. A parametric study is carried out by means of computational thermal fluid dynamic modeling: several channel geometry configurations were compared in terms of time required for analysis, temperature distribution and priming volume. The advantages and disadvantages of such configurations are discussed.

Design of an innovative Polymerase Chain Reaction device based on buoyancy driven flow.

BIANCHI, ELENA;CIOFFI, MARGHERITA;LAGANA', KATIA;DUBINI, GABRIELE ANGELO
2009-01-01

Abstract

Polymerase Chain Reaction (PCR) plays a central role in the field of molecular biology. The miniaturization of PCR systems is promising as it potentially minimizes costly reagent consumption and time required for analysis. In PCR microdevices a sample solution is usually handled by external pumps. An alternative solution relies on temperature-induced density difference in the presence of a body force to induce buoyancy driven flow. This alternative method is easy to be used and does not require expensive setup, but, to date, the thermo-fluid-dynamic field in the micro-channels still needs to be optimized. The present study focuses on the design of micro-channels, having innovative and optimized shapes to obtain proper fluid actuation and DNA sample amplification within buoyancy driven flow PCR devices. A parametric study is carried out by means of computational thermal fluid dynamic modeling: several channel geometry configurations were compared in terms of time required for analysis, temperature distribution and priming volume. The advantages and disadvantages of such configurations are discussed.
2009
9781902316727
9781902316741
File in questo prodotto:
File Dimensione Formato  
MNF2009_63_Bianchi_E.pdf

Accesso riservato

: Altro materiale allegato
Dimensione 552.15 kB
Formato Adobe PDF
552.15 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/547495
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact