We model numerically the mechanical effects of UV induced photo-polymerization in elastomeric artificial lens. The elastomer is originated upon cross-linking of a silicone matrix. UV irradiation of one side of the lens polymerizes selectively a photosensitive macromer, causing local variations of its concentration. The subsequent diffusion of macromers from high concentration to low concentration zones modifies the shape of the lens and thus its dioptric power. In vitro experiments on artificial lens showed that the power change is dependent on UV exposure time, irradiation intensity and light pattern. With the aim to define a numerical tool able to predict the dioptric power adjustment as a function of the UV irradiation parameters, we setup a purely mechanic finite element model of the lens, adopting a hyperelastic material model embedded with eigen-deformations. Numerical simulations of axis-symmetric irradiation closely reproduced the experimental results, in terms of both lens geometry and dioptric power, for positive, negative and lock-in corrections.

A Numerical Model of Light Adjustable Lens

PANDOLFI, ANNA MARINA;
2009-01-01

Abstract

We model numerically the mechanical effects of UV induced photo-polymerization in elastomeric artificial lens. The elastomer is originated upon cross-linking of a silicone matrix. UV irradiation of one side of the lens polymerizes selectively a photosensitive macromer, causing local variations of its concentration. The subsequent diffusion of macromers from high concentration to low concentration zones modifies the shape of the lens and thus its dioptric power. In vitro experiments on artificial lens showed that the power change is dependent on UV exposure time, irradiation intensity and light pattern. With the aim to define a numerical tool able to predict the dioptric power adjustment as a function of the UV irradiation parameters, we setup a purely mechanic finite element model of the lens, adopting a hyperelastic material model embedded with eigen-deformations. Numerical simulations of axis-symmetric irradiation closely reproduced the experimental results, in terms of both lens geometry and dioptric power, for positive, negative and lock-in corrections.
2009
File in questo prodotto:
File Dimensione Formato  
j-2009-lals.pdf

Accesso riservato

: Altro materiale allegato
Dimensione 1.81 MB
Formato Adobe PDF
1.81 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/546516
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact