This paper describes the validation of a model library for the simulation of drum boilers on the basis of static and dynamic experimental data obtained from a small-scale plant. All the steps of the validation process are described in detail, with particular reference to the modelling principles, to the trade-off between model complexity and accuracy, to the solution strategy and to the data-reconciliation policy. The results of the validation have formed an important knowledge base, which might be made available to other research groups.
VALIDATION OF DRUM BOILER MODELS THROUGH COMPLETE DYNAMIC TESTS
LEVA, ALBERTO;MAFFEZZONI, CLAUDIO;
1999-01-01
Abstract
This paper describes the validation of a model library for the simulation of drum boilers on the basis of static and dynamic experimental data obtained from a small-scale plant. All the steps of the validation process are described in detail, with particular reference to the modelling principles, to the trade-off between model complexity and accuracy, to the solution strategy and to the data-reconciliation policy. The results of the validation have formed an important knowledge base, which might be made available to other research groups.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
LevaMaffezzoniBenelli-CEP-1999.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
1.26 MB
Formato
Adobe PDF
|
1.26 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.