The paper deals with methods of processing ECG and respiration signals which aim at detecting parameters whose values may be correlated to normal and diabetic subjects with or without cardiovascular autonomic neuropathy (CAN). Beatto-beat R-R duration values of the ECG and discrete series of respiration are obtained from original signals using a recognition algorithm. Power spectrum analysis (autospectra, cross-spectra and coherence via autoregressive modelling) is carried out on segments of about 200 consecutive cardiac cycles. Spectral parameters of the R-R variability signal are obtained as follows: total power, power of low-frequency (LF) and high-frequency (HF) components, power of the signal which is (or is not) coherent with respiration, in absolute or in percentage values. The experimental protocol considers 40 diabetic patients (21 of whom have diabetic neuropathy) and 14 normals in three different conditions: resting, standing and controlled respiration. The developed spectral parameters seem sensitive enough to differentiate between normal and pathological subjects. These parameters may constitute a quantitative means to be edded to the classical diabetic tests for the diagnosis of cardiovascular autonomic neuropathy.

Spectal analysis of heart rate variability signal and respiration in diabetic subjects

BIANCHI, ANNA MARIA;CERUTTI, SERGIO;
1990-01-01

Abstract

The paper deals with methods of processing ECG and respiration signals which aim at detecting parameters whose values may be correlated to normal and diabetic subjects with or without cardiovascular autonomic neuropathy (CAN). Beatto-beat R-R duration values of the ECG and discrete series of respiration are obtained from original signals using a recognition algorithm. Power spectrum analysis (autospectra, cross-spectra and coherence via autoregressive modelling) is carried out on segments of about 200 consecutive cardiac cycles. Spectral parameters of the R-R variability signal are obtained as follows: total power, power of low-frequency (LF) and high-frequency (HF) components, power of the signal which is (or is not) coherent with respiration, in absolute or in percentage values. The experimental protocol considers 40 diabetic patients (21 of whom have diabetic neuropathy) and 14 normals in three different conditions: resting, standing and controlled respiration. The developed spectral parameters seem sensitive enough to differentiate between normal and pathological subjects. These parameters may constitute a quantitative means to be edded to the classical diabetic tests for the diagnosis of cardiovascular autonomic neuropathy.
1990
Biological signal processing Diabetic neuropathy Heart rate variability Respiration Sympathetic and parasympathetic nervous systems
File in questo prodotto:
File Dimensione Formato  
Med&Biol_Eng&Comp_90.pdf

Accesso riservato

: Publisher’s version
Dimensione 1.72 MB
Formato Adobe PDF
1.72 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/518895
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 64
  • ???jsp.display-item.citation.isi??? 50
social impact