The appearance of terrestrial laser scanners (TLS) has provided a new data source of geometric information. Several TLS allow to be equipped by a calibrated camera, whose images may be directly mapped on the DSM as photo-texture. Here a further improvement is proposed, i.e. the integration of thermal imagery into the 3D model in order to acquire knowledge about internal stratigraphy of walls, floors, ceilings and other ancient structures. Obviously, a fundamental pre-requisite to obtain this task is the calibration of thermal sensor and the orientation of each image into the object reference system of the TLS data. Unfortunately, due to the poor radiometric and geometric quality of themal images, their integration into the TLS 3D model is a complex task; moreover, looking for control points which could be measured on both 3D model and thermal image is not trivial. This leads to the failure of methods performing calibration and orientation in a unique task, such as self-calibration approaches. Calibration has to be performed in laboratory. We have performed the calibration of a thermal camera NEC Thermotracer TH 7102 WX by means of a calibration dig and the computation of inner calibration in a bundle block l.s. adjustment. Data processing has been performed by using a low-cost photogrammetric commercial software.

Integration of multi-source close-range data

GIANINETTO, MARCO;GIUSSANI, ALBERTO;RONCORONI, FABIO;SCAIONI, MARCO
2005-01-01

Abstract

The appearance of terrestrial laser scanners (TLS) has provided a new data source of geometric information. Several TLS allow to be equipped by a calibrated camera, whose images may be directly mapped on the DSM as photo-texture. Here a further improvement is proposed, i.e. the integration of thermal imagery into the 3D model in order to acquire knowledge about internal stratigraphy of walls, floors, ceilings and other ancient structures. Obviously, a fundamental pre-requisite to obtain this task is the calibration of thermal sensor and the orientation of each image into the object reference system of the TLS data. Unfortunately, due to the poor radiometric and geometric quality of themal images, their integration into the TLS 3D model is a complex task; moreover, looking for control points which could be measured on both 3D model and thermal image is not trivial. This leads to the failure of methods performing calibration and orientation in a unique task, such as self-calibration approaches. Calibration has to be performed in laboratory. We have performed the calibration of a thermal camera NEC Thermotracer TH 7102 WX by means of a calibration dig and the computation of inner calibration in a bundle block l.s. adjustment. Data processing has been performed by using a low-cost photogrammetric commercial software.
2005
The International Archive of the Photogrammetry, Remote Sensing and Spatial Information Sciences
Camera Calibration, Thermal Imagery, Cultural Heritage Documentation, Multi-Sensor Data Integration
File in questo prodotto:
File Dimensione Formato  
paper129.pdf

Accesso riservato

Descrizione: full paper
: Altro materiale allegato
Dimensione 529.31 kB
Formato Adobe PDF
529.31 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/517250
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact