This paper describes a method that allows accuracy and bandwidth enhancements in 3-D sound intensity measurements. Commercial 3-D probes are usually set up with three mutually perpendicular 1-D p-p probes and, thus, arranged with six microphones; although sound intensity can be calculated with 15 independent pairs of transducers, only the three “primary” pairs that are aligned with the coordinate system axes. The other 12 “secondary” pairs consist of mutually perpendicularmicrophones, which are placed at a distance that is √ 2 times shorter than the primary one. The main idea of the proposed method is to average the intensity that is measured on primary and secondary pairs. This leads to a larger bandwidth, thanks to the shorter separating distance between secondary pairs. The intrinsic p-p method highfrequency sensitivity loss is partially recovered, starting from the theoretical plane wave expression.Measurements of different axes are weighted with coefficients that are computed by optimizing the measurement uncertainty. Errors that are due to the metrological characteristics of the transducers and the effects of environmental conditions are compensated. Experimental results showed that a p-p probe arranged with half-inch microphones that are placed at a distance of 50 mm allows reliable measurements up to 2.5 kHz, whereas a commercial probe bandwidth with the same configuration is usually 1250 Hz

3D Sound Intensity Measurements: Accuracy Enhancements with Virtual-Instrument-Based Technology

MOSCHIONI, GIOVANNI;SAGGIN, BORTOLINO;TARABINI, MARCO
2008-01-01

Abstract

This paper describes a method that allows accuracy and bandwidth enhancements in 3-D sound intensity measurements. Commercial 3-D probes are usually set up with three mutually perpendicular 1-D p-p probes and, thus, arranged with six microphones; although sound intensity can be calculated with 15 independent pairs of transducers, only the three “primary” pairs that are aligned with the coordinate system axes. The other 12 “secondary” pairs consist of mutually perpendicularmicrophones, which are placed at a distance that is √ 2 times shorter than the primary one. The main idea of the proposed method is to average the intensity that is measured on primary and secondary pairs. This leads to a larger bandwidth, thanks to the shorter separating distance between secondary pairs. The intrinsic p-p method highfrequency sensitivity loss is partially recovered, starting from the theoretical plane wave expression.Measurements of different axes are weighted with coefficients that are computed by optimizing the measurement uncertainty. Errors that are due to the metrological characteristics of the transducers and the effects of environmental conditions are compensated. Experimental results showed that a p-p probe arranged with half-inch microphones that are placed at a distance of 50 mm allows reliable measurements up to 2.5 kHz, whereas a commercial probe bandwidth with the same configuration is usually 1250 Hz
File in questo prodotto:
File Dimensione Formato  
Paper.pdf

Accesso riservato

: Altro materiale allegato
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/516278
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 15