Micro-architected materials are nowadays ubiquitous in many engineering applications, where high performance and simultaneous optimization of multiple functional properties are required. In the field of bone tissue engineering, scaffolds are used to restore bone continuity within defect sites. These defects often span regions with different characteristics, ranging from cortical to trabecular bone. Consequently, an effective scaffold must incorporate spatially distinct architectural regions to mimic the heterogeneous environment of the host tissue. Combining Voronoi-based and TPMS-based architectures offers a promising strategy to recreate two fundamentally different micro-architected environments. However, a smooth and continuous transition between a regular periodic structure (TPMS) and a stochastic structure (Voronoi) has not been reported in the literature yet. In this study, a topology optimization algorithm has been employed to generate a smooth connection between the two architectures within a design composed of two concentric cylindrical regions. Finite element models were developed to identify potential stress concentrations within the hybrid scaffold: three loading conditions (i.e., uniaxial compression, radial compression, and torsion) showed that the transitional region does not exhibit high stress concentrations, confirming its structural soundness. Finally, to demonstrate the manufacturability of the proposed architecture, the scaffolds were fabricated using vat photopolymerization with hydroxyapatite and a hydroxyapatite/calcium phosphate blend. While not intended for a specific anatomical site, this design serves as a challenging test case to evaluate the printing fidelity of architectures characterized by substantially different geometrical features. In both cases, excellent printing fidelity was achieved by a proper printing parameter tuning process, as confirmed through computed micro-tomography analyses.
Regular meets random: A smooth connection between TPMS and Voronoi lattice in 3D printed bioceramic scaffolds
D'Andrea L.;Vena P.
2027-01-01
Abstract
Micro-architected materials are nowadays ubiquitous in many engineering applications, where high performance and simultaneous optimization of multiple functional properties are required. In the field of bone tissue engineering, scaffolds are used to restore bone continuity within defect sites. These defects often span regions with different characteristics, ranging from cortical to trabecular bone. Consequently, an effective scaffold must incorporate spatially distinct architectural regions to mimic the heterogeneous environment of the host tissue. Combining Voronoi-based and TPMS-based architectures offers a promising strategy to recreate two fundamentally different micro-architected environments. However, a smooth and continuous transition between a regular periodic structure (TPMS) and a stochastic structure (Voronoi) has not been reported in the literature yet. In this study, a topology optimization algorithm has been employed to generate a smooth connection between the two architectures within a design composed of two concentric cylindrical regions. Finite element models were developed to identify potential stress concentrations within the hybrid scaffold: three loading conditions (i.e., uniaxial compression, radial compression, and torsion) showed that the transitional region does not exhibit high stress concentrations, confirming its structural soundness. Finally, to demonstrate the manufacturability of the proposed architecture, the scaffolds were fabricated using vat photopolymerization with hydroxyapatite and a hydroxyapatite/calcium phosphate blend. While not intended for a specific anatomical site, this design serves as a challenging test case to evaluate the printing fidelity of architectures characterized by substantially different geometrical features. In both cases, excellent printing fidelity was achieved by a proper printing parameter tuning process, as confirmed through computed micro-tomography analyses.| File | Dimensione | Formato | |
|---|---|---|---|
|
2027_ActaMat.pdf
accesso aperto
:
Publisher’s version
Dimensione
3.53 MB
Formato
Adobe PDF
|
3.53 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



