DC microgrids represent a promising solution for a more direct and efficient integration of renewable energy sources, particularly in scenarios where the load profile can be forecast with sufficient accuracy. The penetration of inverter-connected resources produces significant harmonic pollution also at DC level, making necessary the implementation of proper DC power quality monitoring infrastructures. While some improvements have been done on the algorithmic side, the characterization of the sensor stage is still limited to the calibration with pure DC signals. This paper considers the problem of the accuracy verification robustness of Open-Loop Hall effect current transducers with three different current injection methods. The preliminary results suggest the importance of the signal injection as well as the non negligible dependencies between DC and AC components.

Accuracy Verification Robustness of Commercial O/L Hall Effect Sensors for AC Ripple Measurements in DC Grids

Demetrio, A.;Faifer, M.;Laurano, C.;Ottoboni, R.;Toscani, S.
2026-01-01

Abstract

DC microgrids represent a promising solution for a more direct and efficient integration of renewable energy sources, particularly in scenarios where the load profile can be forecast with sufficient accuracy. The penetration of inverter-connected resources produces significant harmonic pollution also at DC level, making necessary the implementation of proper DC power quality monitoring infrastructures. While some improvements have been done on the algorithmic side, the characterization of the sensor stage is still limited to the calibration with pure DC signals. This paper considers the problem of the accuracy verification robustness of Open-Loop Hall effect current transducers with three different current injection methods. The preliminary results suggest the importance of the signal injection as well as the non negligible dependencies between DC and AC components.
2026
Conference Record - IEEE Instrumentation and Measurement Technology Conference
DC Measurement
Frequency Response
Hall-Effect Sensors
Power Quality
Transducer Error
File in questo prodotto:
File Dimensione Formato  
Accuracy_Verification_Robustness_of_Commercial_O_L_Hall_Effect_Sensors_for_AC_Ripple_Measurements_in_DC_Grids.pdf

Accesso riservato

: Publisher’s version
Dimensione 681.62 kB
Formato Adobe PDF
681.62 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1333130
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact