In the context of Industry 5.0, the possibility of reliably monitoring the physiological well-being of industrial workers represents a growing priority. Focusing on the exploitation of non-invasive wearable devices, this study introduces a fully printed, flexible humidity sensor designed for continuous sweat-rate monitoring. The solution was specifically designed to work in low-perspiration conditions, which are common during near-rest or at-rest states. The device integrates inkjet-printed silver interdigitated electrodes coated with a Cobalt-based metal-organic framework active layer, which provides high sensitivity through efficient water-binding kinetics. Laboratory characterization confirmed a linear response between 50% and 95% relative humidity (RH), with an average sensitivity of 0.06 Log(Ω)/% RH. In vivo validation demonstrated that the proposed solution effectively captures the skin-sensor microclimate humidity (ranging from 80% to 95% RH) and closely correlates with the tonic phase of Electrodermal Activity signals. These findings supported the validation of the proposed platform as a reliable, pump-free microfluidic solution for tracking the subtle transition from basal perspiration to active sweat production.

A Fully Printed Cobalt-Based Metal-Organic Framework Humidity Sensor for Wearable Sweat-Rate Monitoring in Industrial Settings

Lopomo, Nicola Francesco;
2026-01-01

Abstract

In the context of Industry 5.0, the possibility of reliably monitoring the physiological well-being of industrial workers represents a growing priority. Focusing on the exploitation of non-invasive wearable devices, this study introduces a fully printed, flexible humidity sensor designed for continuous sweat-rate monitoring. The solution was specifically designed to work in low-perspiration conditions, which are common during near-rest or at-rest states. The device integrates inkjet-printed silver interdigitated electrodes coated with a Cobalt-based metal-organic framework active layer, which provides high sensitivity through efficient water-binding kinetics. Laboratory characterization confirmed a linear response between 50% and 95% relative humidity (RH), with an average sensitivity of 0.06 Log(Ω)/% RH. In vivo validation demonstrated that the proposed solution effectively captures the skin-sensor microclimate humidity (ranging from 80% to 95% RH) and closely correlates with the tonic phase of Electrodermal Activity signals. These findings supported the validation of the proposed platform as a reliable, pump-free microfluidic solution for tracking the subtle transition from basal perspiration to active sweat production.
2026
Conference Proceedings - 2026 IEEE International Workshop on Metrology for Industry 4.0 and IoT, MetroInd4.0 and IoT 2026
Metal-Organic Frameworks (MOFs)
Sweat-rate monitoring
Wearable sensors
File in questo prodotto:
File Dimensione Formato  
A_Fully_Printed_Cobalt-Based_Metal-Organic_Framework_Humidity_Sensor_for_Wearable_Sweat-Rate_Monitoring_in_Industrial_Settings.pdf

Accesso riservato

Descrizione: Publisher's Version
: Publisher’s version
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1330828
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 0
social impact