Recent earthquakes have highlighted the vulnerability of unreinforced masonry buildings, as their structural integrity is often compromised by weak connections between walls. Post-installed bonded fasteners have become a popular, cost-effective retrofitting technique, yet there is a significant lack of research and clear design guidelines for their applications. To address this issue, an experimental study was conducted on four full-scale T-shaped masonry wall specimens, intentionally built with weak connections to replicate common practice. The specimens were first tested under monotonic out-of-plane loading without reinforcement and subsequently retrofitted with a bonded fastener system (rebars and a hybrid adhesive) and subjected to cyclic loading. The study investigated the effect of two key design parameters: the embedment depth (85 cm vs. 65 cm) and the number of connectors (8, 3, or 2 rebars). The results showed that, although all retrofitted configurations achieved a similar range for the maximum horizontal load, only the higher number of fasteners guaranteed the necessary monolithic behavior that dictates the overall performance and failure mode.

Experimental study on fastener strengthened masonry t-wall

Manuela Scamardo;Sara Cattaneo;Pietro Crespi.
2026-01-01

Abstract

Recent earthquakes have highlighted the vulnerability of unreinforced masonry buildings, as their structural integrity is often compromised by weak connections between walls. Post-installed bonded fasteners have become a popular, cost-effective retrofitting technique, yet there is a significant lack of research and clear design guidelines for their applications. To address this issue, an experimental study was conducted on four full-scale T-shaped masonry wall specimens, intentionally built with weak connections to replicate common practice. The specimens were first tested under monotonic out-of-plane loading without reinforcement and subsequently retrofitted with a bonded fastener system (rebars and a hybrid adhesive) and subjected to cyclic loading. The study investigated the effect of two key design parameters: the embedment depth (85 cm vs. 65 cm) and the number of connectors (8, 3, or 2 rebars). The results showed that, although all retrofitted configurations achieved a similar range for the maximum horizontal load, only the higher number of fasteners guaranteed the necessary monolithic behavior that dictates the overall performance and failure mode.
2026
REHABEND 2026 CONSTRUCTION PATHOLOGY, REHABILITATION TECHNOLOGY AND HERITAGE MANAGEMENT - BOOK OF PAPERS
masonry retrofitting; cyclic loading; bonded fastener; full-scale testing; wall-to-wall connections.
File in questo prodotto:
File Dimensione Formato  
2026_Experimental study on fastener strengthened masonry t-wall Rehabend.pdf

Accesso riservato

: Publisher’s version
Dimensione 785.29 kB
Formato Adobe PDF
785.29 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1319738
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact