Recent earthquakes have highlighted the vulnerability of unreinforced masonry buildings, as their structural integrity is often compromised by weak connections between walls. Post-installed bonded fasteners have become a popular, cost-effective retrofitting technique, yet there is a significant lack of research and clear design guidelines for their applications. To address this issue, an experimental study was conducted on four full-scale T-shaped masonry wall specimens, intentionally built with weak connections to replicate common practice. The specimens were first tested under monotonic out-of-plane loading without reinforcement and subsequently retrofitted with a bonded fastener system (rebars and a hybrid adhesive) and subjected to cyclic loading. The study investigated the effect of two key design parameters: the embedment depth (85 cm vs. 65 cm) and the number of connectors (8, 3, or 2 rebars). The results showed that, although all retrofitted configurations achieved a similar range for the maximum horizontal load, only the higher number of fasteners guaranteed the necessary monolithic behavior that dictates the overall performance and failure mode.
Experimental study on fastener strengthened masonry t-wall
Manuela Scamardo;Sara Cattaneo;Pietro Crespi.
2026-01-01
Abstract
Recent earthquakes have highlighted the vulnerability of unreinforced masonry buildings, as their structural integrity is often compromised by weak connections between walls. Post-installed bonded fasteners have become a popular, cost-effective retrofitting technique, yet there is a significant lack of research and clear design guidelines for their applications. To address this issue, an experimental study was conducted on four full-scale T-shaped masonry wall specimens, intentionally built with weak connections to replicate common practice. The specimens were first tested under monotonic out-of-plane loading without reinforcement and subsequently retrofitted with a bonded fastener system (rebars and a hybrid adhesive) and subjected to cyclic loading. The study investigated the effect of two key design parameters: the embedment depth (85 cm vs. 65 cm) and the number of connectors (8, 3, or 2 rebars). The results showed that, although all retrofitted configurations achieved a similar range for the maximum horizontal load, only the higher number of fasteners guaranteed the necessary monolithic behavior that dictates the overall performance and failure mode.| File | Dimensione | Formato | |
|---|---|---|---|
|
2026_Experimental study on fastener strengthened masonry t-wall Rehabend.pdf
Accesso riservato
:
Publisher’s version
Dimensione
785.29 kB
Formato
Adobe PDF
|
785.29 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.