Wearable devices running Human Activity Recognition (HAR) on Inertial Measurement Units (IMUs) waste energy by performing continuous classification for each window, even during long periods of unchanged activity. We address this with a lightweight change-detection gate: a non-parametric algorithm based on dynamic template matching that runs continuously at only approximately 16 kFLOPs per step, requires no offline training, and does not need prior definition of target activity classes. The gate invokes the full HAR network only when it detects an activity change, reducing the computational load by over 67% in realistic monitoring settings. The algorithm is evaluated on smart glasses, smartwatch, and smartphone data, requiring only a brief device-specific calibration phase. The gate achieves 98% sensitivity on UCA-EHAR, ensuring no genuine activity transition is missed, while 75 % specificity keeps unnecessary HAR invocations low. Results on WISDM are 97% sensitivity and 76% specificity, demonstrating robustness and flexibility to various settings.
An Algorithm for On-Sensor Agnostic Detection of Changes in Human Activity for Ultra-Low-Power Applications
Rimoldi, Sara;Vecchi, Arianna De;Shalby, Hazem Hesham Yousef;Villa, Federica
2026-01-01
Abstract
Wearable devices running Human Activity Recognition (HAR) on Inertial Measurement Units (IMUs) waste energy by performing continuous classification for each window, even during long periods of unchanged activity. We address this with a lightweight change-detection gate: a non-parametric algorithm based on dynamic template matching that runs continuously at only approximately 16 kFLOPs per step, requires no offline training, and does not need prior definition of target activity classes. The gate invokes the full HAR network only when it detects an activity change, reducing the computational load by over 67% in realistic monitoring settings. The algorithm is evaluated on smart glasses, smartwatch, and smartphone data, requiring only a brief device-specific calibration phase. The gate achieves 98% sensitivity on UCA-EHAR, ensuring no genuine activity transition is missed, while 75 % specificity keeps unnecessary HAR invocations low. Results on WISDM are 97% sensitivity and 76% specificity, demonstrating robustness and flexibility to various settings.| File | Dimensione | Formato | |
|---|---|---|---|
|
BEAT_434-2.pdf
Accesso riservato
Dimensione
826.62 kB
Formato
Adobe PDF
|
826.62 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.



