Single-lap shear joints made from fabric T300/polyphenylene sulfide (T300/PPS) and unidirectional T700/low-melt polyaryletherketone (T700/LM-PAEK) laminates are joined via induction and conduction welding at different processing temperatures. The joints are tested experimentally to investigate the influence of the processing temperature on the damage evolution in the specimens which is tracked using digital image correlation. Cracks grow rapidly in the unwelded parts of the joint interface but assume a stable steady-state propagation rate when reaching the fully welded overlap region. It is found that higher welding temperatures lead to longer weld lengths, which improve the strength and stiffness of the specimens and delay damage initiation. An accelerated crack growth rate indicates that the structure is close to its ultimate load after which the joint fails abruptly as the crack growth becomes unstable. Induction welding temperatures at the upper end of the recommended processing window (330 degrees C for T300/PPS and 385 degrees C for T700/LM-PAEK) result in the joints with the highest load-carrying capacity and slowest crack propagation, but also the least damage tolerance.

Experimental Evaluation of Induction- and Conduction-Welded Thermoplastic Composite Single-Lap Shear Joints

Bisagni, Chiara
2026-01-01

Abstract

Single-lap shear joints made from fabric T300/polyphenylene sulfide (T300/PPS) and unidirectional T700/low-melt polyaryletherketone (T700/LM-PAEK) laminates are joined via induction and conduction welding at different processing temperatures. The joints are tested experimentally to investigate the influence of the processing temperature on the damage evolution in the specimens which is tracked using digital image correlation. Cracks grow rapidly in the unwelded parts of the joint interface but assume a stable steady-state propagation rate when reaching the fully welded overlap region. It is found that higher welding temperatures lead to longer weld lengths, which improve the strength and stiffness of the specimens and delay damage initiation. An accelerated crack growth rate indicates that the structure is close to its ultimate load after which the joint fails abruptly as the crack growth becomes unstable. Induction welding temperatures at the upper end of the recommended processing window (330 degrees C for T300/PPS and 385 degrees C for T700/LM-PAEK) result in the joints with the highest load-carrying capacity and slowest crack propagation, but also the least damage tolerance.
2026
thermoplastic welding
single-lap shear joint
digital image correlation
crack growth
File in questo prodotto:
File Dimensione Formato  
SCHIA01-26.pdf

accesso aperto

Dimensione 6.05 MB
Formato Adobe PDF
6.05 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1315445
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact