In this study, a semi-hermetic compressor designed for R744 is tested using R744/R290 mixtures with mass composition of 100/0% (pure R744, baseline), 95/5%, 90/10%, 85/15%, and 80/20%. Tests are conducted under steady-state conditions for various operating points, including different saturation suction temperatures and gas cooler pressures, with a fixed superheat of 10 K and constant compressor frequency. The results show that the refrigerant mass flow rate decreases with increasing propane content. Power consumption exhibits a complex and non-linear behavior: at low propane concentrations no clear trend is observed, whereas at higher propane contents a reduction in power consumption is measured. The discharge temperature is higher for the R744/R290 mixtures compared to pure R744. Regarding performance, volumetric and global efficiencies show no significant differences up to 15% propane, while a noticeable increase is observed at 20% propane, indicating an overall improvement in compressor performance at higher propane concentrations.

Experimental analysis of the performance of a semi-hermetic reciprocating compressor working with R744/R290 mixtures

D'Ignazi, Chiara;Molinaroli, Luca
2026-01-01

Abstract

In this study, a semi-hermetic compressor designed for R744 is tested using R744/R290 mixtures with mass composition of 100/0% (pure R744, baseline), 95/5%, 90/10%, 85/15%, and 80/20%. Tests are conducted under steady-state conditions for various operating points, including different saturation suction temperatures and gas cooler pressures, with a fixed superheat of 10 K and constant compressor frequency. The results show that the refrigerant mass flow rate decreases with increasing propane content. Power consumption exhibits a complex and non-linear behavior: at low propane concentrations no clear trend is observed, whereas at higher propane contents a reduction in power consumption is measured. The discharge temperature is higher for the R744/R290 mixtures compared to pure R744. Regarding performance, volumetric and global efficiencies show no significant differences up to 15% propane, while a noticeable increase is observed at 20% propane, indicating an overall improvement in compressor performance at higher propane concentrations.
2026
Binary mixtures
Experimental analysis
Performance
R290
R744
Reciprocating compressor
Zeotropic mixtures
File in questo prodotto:
File Dimensione Formato  
Experimental analysis of the performance of a semi-hermetic reciprocating compressor working with R744-R290 mixtures.pdf

accesso aperto

Descrizione: Articolo pubblicato
: Publisher’s version
Dimensione 3 MB
Formato Adobe PDF
3 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1315188
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact