Background: Research on vibrations induced by running has gained significant attention due to its implications for athletes’ performance, injury prevention, and overall well-being. Distance running exposes the body to repetitive impulsive forces, causing significant vibrations to travel through physiological systems and biomechanical structures. These vibrations increase fatigue and the risk of injury. Although it has gained importance, research on induced vibration during running and wearable equipment for monitoring is scarce. This study aims to evaluate the performance of a measurement system for monitoring the acceleration levels of induced vibrations during long-distance running, exploring the capability of non-invasive wearable devices to characterise vibration transmissibility and exposure. Moreover, a preliminary quantitative assessment of induced vibration levels for an indoor testing scenario is given. Methods: Metrological characterisation of Xsens Motion Trackers Awinda (MTw), off-the-shelf inertial magnetic motion trackers, was performed by measuring the sensors’ frequency bandwidth in a controlled environment, providing logarithmic sweep sine excitations at different levels (2 g, 5 g, 7 g, where g is meant to be the gravitational acceleration). A testing protocol for indoor testing was derived from the literature, allowing characterisation of the sensors’ behaviour in terms of vibration transmissibility and exposure detection in the intended application. Time domain and frequency domain analyses were conducted by following the ISO 2631 standard guideline for vibration exposure assessment, and measurement uncertainty was defined, either for the dynamic correction of the sensors’ frequency behaviour or for the computed time and frequency domain metrics. In this framework, a treadmill-based test was conducted. The aim was to evaluate the Xsens sensors’ performance in measuring vibration dose exposure and transmissibility. Three MTws were placed on the subject’s right tibia, back, and forehead using elastic bands. A 25-year-old female amateur runner completed a series of tests consisting of walking for 1 min at 3.5 km/h (instrumentation setup), followed by running at two speeds (8 km/h and 11 km/h) for 2–4 min per trial, with 5 min rest periods between tests. Conclusions: The tested measurement system showed promising results due to its capability to assess vibration exposure during sports activities, but dynamic correction was found to be mandatory for accurate vibration level assessment. The main outcome of this study is a method for characterising the accelerometers embedded in the proposed devices, along with an analysis strategy for future testing campaigns. Thanks to the portability of IMUs (inertial measurement units), this approach enables the evaluation of induced vibrations during in-field running measurements.

Assessment of Xsens Motion Trackers’ Accuracy to Measure Induced Vibrations During Endurance Running

Martina C.;Appiani A.;Scaccabarozzi D.
2026-01-01

Abstract

Background: Research on vibrations induced by running has gained significant attention due to its implications for athletes’ performance, injury prevention, and overall well-being. Distance running exposes the body to repetitive impulsive forces, causing significant vibrations to travel through physiological systems and biomechanical structures. These vibrations increase fatigue and the risk of injury. Although it has gained importance, research on induced vibration during running and wearable equipment for monitoring is scarce. This study aims to evaluate the performance of a measurement system for monitoring the acceleration levels of induced vibrations during long-distance running, exploring the capability of non-invasive wearable devices to characterise vibration transmissibility and exposure. Moreover, a preliminary quantitative assessment of induced vibration levels for an indoor testing scenario is given. Methods: Metrological characterisation of Xsens Motion Trackers Awinda (MTw), off-the-shelf inertial magnetic motion trackers, was performed by measuring the sensors’ frequency bandwidth in a controlled environment, providing logarithmic sweep sine excitations at different levels (2 g, 5 g, 7 g, where g is meant to be the gravitational acceleration). A testing protocol for indoor testing was derived from the literature, allowing characterisation of the sensors’ behaviour in terms of vibration transmissibility and exposure detection in the intended application. Time domain and frequency domain analyses were conducted by following the ISO 2631 standard guideline for vibration exposure assessment, and measurement uncertainty was defined, either for the dynamic correction of the sensors’ frequency behaviour or for the computed time and frequency domain metrics. In this framework, a treadmill-based test was conducted. The aim was to evaluate the Xsens sensors’ performance in measuring vibration dose exposure and transmissibility. Three MTws were placed on the subject’s right tibia, back, and forehead using elastic bands. A 25-year-old female amateur runner completed a series of tests consisting of walking for 1 min at 3.5 km/h (instrumentation setup), followed by running at two speeds (8 km/h and 11 km/h) for 2–4 min per trial, with 5 min rest periods between tests. Conclusions: The tested measurement system showed promising results due to its capability to assess vibration exposure during sports activities, but dynamic correction was found to be mandatory for accurate vibration level assessment. The main outcome of this study is a method for characterising the accelerometers embedded in the proposed devices, along with an analysis strategy for future testing campaigns. Thanks to the portability of IMUs (inertial measurement units), this approach enables the evaluation of induced vibrations during in-field running measurements.
2026
endurance training; human response to vibration monitoring; IMU for sport applications; long-distance running; MEMS; running-related injuries (RRIs); wearable devices;
File in questo prodotto:
File Dimensione Formato  
jfmk-11-00082.pdf

accesso aperto

: Publisher’s version
Dimensione 2.46 MB
Formato Adobe PDF
2.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1312176
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact