The effect of the different components that contribute to the detection capability of a real-time hyperspectral imager, is studied and characterized experimentally, using a high energy-resolution detection system, based on a pulsed-reset low-noise charge sensitive amplifier and a CdTe pixel detector. The dependency on the system output count-rate from the tube operating point, and the estimate of the corresponding input-count rate is shown at first, while also presenting the energy resolution dependency resulting from the different flux conditions. The system is shown to be able to operate at output count rates as high as 2.6 Mcps/pixel (4.0 Mcps/mm2) with a minimum peaking time of 50 ns, and an optimum FWHM of 470 eV on the W-La1 line under low-rate conditions. The detection capability of the system is then evaluated using short (100 ms) multiple acquisitions of a single pixel spectra of a soft-cheese sample, with and without a 1 mm thick HighDensity Polyethylene Contaminant (HDPE), reconstructing a simulated hyperspectral image, comparing the result with respect to a standard counting image. The contrast between the contaminated and compliant product regions appears to be enhanced by the usage of the spectral information in the hyperspectral image.

Real-Time Hyperspectral Imaging Performances with Low-Noise Charge Amplifier and CdTe X-Ray Detector for Inline Product Inspection

Mele, F.;Quercia, J.;Bertuccio, G.
2025-01-01

Abstract

The effect of the different components that contribute to the detection capability of a real-time hyperspectral imager, is studied and characterized experimentally, using a high energy-resolution detection system, based on a pulsed-reset low-noise charge sensitive amplifier and a CdTe pixel detector. The dependency on the system output count-rate from the tube operating point, and the estimate of the corresponding input-count rate is shown at first, while also presenting the energy resolution dependency resulting from the different flux conditions. The system is shown to be able to operate at output count rates as high as 2.6 Mcps/pixel (4.0 Mcps/mm2) with a minimum peaking time of 50 ns, and an optimum FWHM of 470 eV on the W-La1 line under low-rate conditions. The detection capability of the system is then evaluated using short (100 ms) multiple acquisitions of a single pixel spectra of a soft-cheese sample, with and without a 1 mm thick HighDensity Polyethylene Contaminant (HDPE), reconstructing a simulated hyperspectral image, comparing the result with respect to a standard counting image. The contrast between the contaminated and compliant product regions appears to be enhanced by the usage of the spectral information in the hyperspectral image.
2025
2025 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector Conference (RTSD)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1310372
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 0
social impact