Coronary artery bypass grafting is a widely used treatment for coronary artery disease that relies on small-caliber vascular grafts (<6 mm). The need for valuable alternatives to autologous grafts has increased the number of studies evaluating the performance of new grafts. Although animal models are still used in preclinical testing, they present the significant limitation of poorly reproducing the counterphase dynamics characteristic of the physiological human condition, highlighting a critical gap in accurately mimicking human coronary hemodynamics. In this scenario, the present work proposes the development of a compact and modular in vitro culture system designed to reproduce the physiological stimuli characteristic of human coronary circulation, particularly the counterphase dynamics between pressure and flow observed in vivo. The system integrates a culture chamber accommodating six tubular samples, allowing for automated rotational cell seeding and dynamic perfusion. Precise fluid-induced mechanical stimuli are applied through an electronic control unit, powered by four ESP32 microcontrollers, which controls peristaltic pumps, a proportional pinch valve, and a stepper motor. The peristaltic pumps and the pinch valve, the latter provided with a closed-loop feedback algorithm, enable the replication of pulsatile coronary conditions (1 Hz heart rate, 80-120 mmHg pressure range, and 100-300 ml/min flow rate range), whereas the stepper motor allows for a controlled rotation of the culture chamber. Bench testing validated the ability of the system to generate reproducible pressure-flow waveforms, including the coronary counterphase pattern, confirming its potential to assist preclinical research. The modular, incubator-compatible design allows for efficient sample handling, triplicate experimentation, and integration of biological protocols. Future work will focus on biological validation and optimization of the system for vascular tissue engineering.

An Innovative in Vitro Model to Replicate Coronary Hemodynamics for Vascular Tissue Engineering Applications

Lucrezia Moro;Alessia Sofia Bolandrina;Elia Pederzani;Gianfranco Beniamino Fiore;Monica Soncini
2025-01-01

Abstract

Coronary artery bypass grafting is a widely used treatment for coronary artery disease that relies on small-caliber vascular grafts (<6 mm). The need for valuable alternatives to autologous grafts has increased the number of studies evaluating the performance of new grafts. Although animal models are still used in preclinical testing, they present the significant limitation of poorly reproducing the counterphase dynamics characteristic of the physiological human condition, highlighting a critical gap in accurately mimicking human coronary hemodynamics. In this scenario, the present work proposes the development of a compact and modular in vitro culture system designed to reproduce the physiological stimuli characteristic of human coronary circulation, particularly the counterphase dynamics between pressure and flow observed in vivo. The system integrates a culture chamber accommodating six tubular samples, allowing for automated rotational cell seeding and dynamic perfusion. Precise fluid-induced mechanical stimuli are applied through an electronic control unit, powered by four ESP32 microcontrollers, which controls peristaltic pumps, a proportional pinch valve, and a stepper motor. The peristaltic pumps and the pinch valve, the latter provided with a closed-loop feedback algorithm, enable the replication of pulsatile coronary conditions (1 Hz heart rate, 80-120 mmHg pressure range, and 100-300 ml/min flow rate range), whereas the stepper motor allows for a controlled rotation of the culture chamber. Bench testing validated the ability of the system to generate reproducible pressure-flow waveforms, including the coronary counterphase pattern, confirming its potential to assist preclinical research. The modular, incubator-compatible design allows for efficient sample handling, triplicate experimentation, and integration of biological protocols. Future work will focus on biological validation and optimization of the system for vascular tissue engineering.
2025
An Innovative in Vitro Model to Replicate Coronary Hemodynamics for Vascular Tissue Engineering Applications
File in questo prodotto:
File Dimensione Formato  
ABSTRACT_3R_finale.pdf

Accesso riservato

Dimensione 142.98 kB
Formato Adobe PDF
142.98 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1310048
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact