In the past few decades, researchers have developed various pressure management techniques to control pressure, recover energy, and reduce leakage in water distribution networks. Most of these techniques have been developed and validated under numerical conditions. Only rarely it has been possible to receive feedback from the field after application, creating a gap between numerical approach and field application. To address this gap, the Experimental Network for the Evaluation of the Digital Twin (E-NET) has been developing at Politecnico di Milano as a scaled laboratory model of a widespread numerical benchmark network to create a bridge between numerical simulations and laboratory practice. In this study, a well-known technique for Pressure Reducing Valves (PRVs) placement was applied to both the original benchmark and the scaled laboratory (E-NET) networks. It was confirmed that leakage reduction, as well as the optimal location and setting of PRVs, remain consistent across both systems. This demonstrates the feasibility of developing methodologies based on the scaled benchmark, thereby opening the way for experimental verification of the proposed methods.

Effectiveness of a Scaled WDN Benchmark for Optimization Applications

Stefano Malavasi;Abazar Fathi;Giacomo Ferrarese
2025-01-01

Abstract

In the past few decades, researchers have developed various pressure management techniques to control pressure, recover energy, and reduce leakage in water distribution networks. Most of these techniques have been developed and validated under numerical conditions. Only rarely it has been possible to receive feedback from the field after application, creating a gap between numerical approach and field application. To address this gap, the Experimental Network for the Evaluation of the Digital Twin (E-NET) has been developing at Politecnico di Milano as a scaled laboratory model of a widespread numerical benchmark network to create a bridge between numerical simulations and laboratory practice. In this study, a well-known technique for Pressure Reducing Valves (PRVs) placement was applied to both the original benchmark and the scaled laboratory (E-NET) networks. It was confirmed that leakage reduction, as well as the optimal location and setting of PRVs, remain consistent across both systems. This demonstrates the feasibility of developing methodologies based on the scaled benchmark, thereby opening the way for experimental verification of the proposed methods.
2025
proceedings of CSDU CSSI days 2025
Pressure Reducing Valve, Optimization, Leakage, E-NET
File in questo prodotto:
File Dimensione Formato  
250926_CSDU-CSSI DAYS 25_ENET_2.pdf

Accesso riservato

: Publisher’s version
Dimensione 364.87 kB
Formato Adobe PDF
364.87 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1308988
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact