A simple and rapid approach to analyse the failure hazard of historical masonry vaults is presented, using a paradigmatic case study from a massive urban aggregate in Piacenza (Emilia Romagna, Italy). The curved structure under examination is a cloister vault with a considerable span, over which a wall was constructed in the key position. The urgency of a stability assessment to prevent failure is evident. The geometrical characteristics and some material information were obtained through in situ surveys. To assess its stability and determine the risk of failure a 2D finite element model is proposed, in which the bricks are discretized using 4-noded elastic elements in plane stress, and the mortar joints are characterized by (i) orthotropic shell elements coupled with (ii) ductile cutoff bars. The backfill is considered in the model by using a system of equivalent forces reproducing both soil self-weight and horizontal earth pressure. Additionally, a possible retrofitting intervention using Carbon Fiber Reinforced Polymer (CFRP) is tested and it is modelled with elastic perfectly ductile cutoff bars placed at the intrados of the vault and connected to each node of the mesh, ensuring a perfect bond between substrate and reinforcement. After a thorough analysis of the results, including force- displacement curves and a detailed examination of the failure mechanisms, an assessment of the cloister vault is provided.

ON THE NONLINEAR BEHAVIOR OF MASONRY CLOISTER VAULTS: A CASE STUDY IN PIACENZA, EMILIA ROMAGNA, ITALY

Pingaro N.;Buzzetti M.;Milani G.
2024-01-01

Abstract

A simple and rapid approach to analyse the failure hazard of historical masonry vaults is presented, using a paradigmatic case study from a massive urban aggregate in Piacenza (Emilia Romagna, Italy). The curved structure under examination is a cloister vault with a considerable span, over which a wall was constructed in the key position. The urgency of a stability assessment to prevent failure is evident. The geometrical characteristics and some material information were obtained through in situ surveys. To assess its stability and determine the risk of failure a 2D finite element model is proposed, in which the bricks are discretized using 4-noded elastic elements in plane stress, and the mortar joints are characterized by (i) orthotropic shell elements coupled with (ii) ductile cutoff bars. The backfill is considered in the model by using a system of equivalent forces reproducing both soil self-weight and horizontal earth pressure. Additionally, a possible retrofitting intervention using Carbon Fiber Reinforced Polymer (CFRP) is tested and it is modelled with elastic perfectly ductile cutoff bars placed at the intrados of the vault and connected to each node of the mesh, ensuring a perfect bond between substrate and reinforcement. After a thorough analysis of the results, including force- displacement curves and a detailed examination of the failure mechanisms, an assessment of the cloister vault is provided.
2024
World Congress in Computational Mechanics and ECCOMAS Congress
Cloister Vaults
Finite element method (FEM)
Masonry
Nonlinear analysis
File in questo prodotto:
File Dimensione Formato  
2024_ECCOMAS_2.pdf

Accesso riservato

Descrizione: 2024_ECCOMAS_Pin_Buz_Mil
: Publisher’s version
Dimensione 1.92 MB
Formato Adobe PDF
1.92 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1306231
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact