This paper treats the use of magnetostrictive shunt to the aim of vibration control when a primary system is excited by an external disturbance. It is shown that when the primary system is coupled with an magnetostrictive element surrounded by a coil, and this coil is shunted with a proper electric impedance, vibration reduction is achieved. To model the coupled system, an approach already used for piezoelectric shunt is employed, defining similar non-dimensional parameters which are then shown to drive the attenuation performance and the shunt tuning, exactly as for piezoelectric shunt. This model constitutes an improvement compared to the models available in the literature and shows that a strict parallelism exists between the two considered types of shunt control. Nevertheless, when practical applications are considered, it comes out that some adjustments are needed for the model of magnetostrictive shunt, mainly due to the magnetic losses in the shunted coil. This makes magnetostrictive shunt and piezoelectric shunt slightly different, and the paper proposes a possible upgrade for the model of magnetostrictive system. All the theoretical results related to magnetostrictive shunt are validated by means of a tailored set-up, focusing on the case of mono-modal control and using both resistive and resonant shunt. The work also defines which are the main limits of magnetostrictive shunt compared to piezoelectric shunt, and it resulted that the main limitations are primarily related to the inability to achieve optimal tuning when low frequency modes need to be attenuated. The proposed model of magnetostrictive shunt can also be used for other applications, such as, e.g., structural health monitoring.

MAGNETOSTRICTIVE SHUNT VERSUS PIEZOELECTRIC SHUNT: A COMPARISON

S. Manzoni
2025-01-01

Abstract

This paper treats the use of magnetostrictive shunt to the aim of vibration control when a primary system is excited by an external disturbance. It is shown that when the primary system is coupled with an magnetostrictive element surrounded by a coil, and this coil is shunted with a proper electric impedance, vibration reduction is achieved. To model the coupled system, an approach already used for piezoelectric shunt is employed, defining similar non-dimensional parameters which are then shown to drive the attenuation performance and the shunt tuning, exactly as for piezoelectric shunt. This model constitutes an improvement compared to the models available in the literature and shows that a strict parallelism exists between the two considered types of shunt control. Nevertheless, when practical applications are considered, it comes out that some adjustments are needed for the model of magnetostrictive shunt, mainly due to the magnetic losses in the shunted coil. This makes magnetostrictive shunt and piezoelectric shunt slightly different, and the paper proposes a possible upgrade for the model of magnetostrictive system. All the theoretical results related to magnetostrictive shunt are validated by means of a tailored set-up, focusing on the case of mono-modal control and using both resistive and resonant shunt. The work also defines which are the main limits of magnetostrictive shunt compared to piezoelectric shunt, and it resulted that the main limitations are primarily related to the inability to achieve optimal tuning when low frequency modes need to be attenuated. The proposed model of magnetostrictive shunt can also be used for other applications, such as, e.g., structural health monitoring.
2025
Proceedings of SMART 2025 - 11th ECCOMAS Thematic Conference on Smart Structures and Materials
File in questo prodotto:
File Dimensione Formato  
SMART_magnetostr.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 423.64 kB
Formato Adobe PDF
423.64 kB Adobe PDF   Visualizza/Apri
201001.pdf

accesso aperto

: Publisher’s version
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1304926
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 0
social impact