This paper probes the validity up to 15 kHz of the analytical formulae published in the CIGRE Technical Brochure 908 related to the calculation of the armour losses in single-armoured AC cables, which have been tested in the Brochure at 50 Hz only. After briefly reviewing the theoretical background and carefully explaining the approximations performed by the Brochure, it is shown that for a typical cable, the analytical formulae are reasonably accurate in the estimation of losses up to 15 kHz, but the absolute error increases linearly with frequency.

Probing armour losses formulae from CIGRE technical Brochure 908

P. Cambareri;L. Di Rienzo;C. de Falco;
2026-01-01

Abstract

This paper probes the validity up to 15 kHz of the analytical formulae published in the CIGRE Technical Brochure 908 related to the calculation of the armour losses in single-armoured AC cables, which have been tested in the Brochure at 50 Hz only. After briefly reviewing the theoretical background and carefully explaining the approximations performed by the Brochure, it is shown that for a typical cable, the analytical formulae are reasonably accurate in the estimation of losses up to 15 kHz, but the absolute error increases linearly with frequency.
2026
Submarine cables · Eddy currents · Ohmic losses · Magnetic losses
File in questo prodotto:
File Dimensione Formato  
2026_EE_Cambareri_Bechis_de_Falco.pdf

accesso aperto

Dimensione 1.14 MB
Formato Adobe PDF
1.14 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1303651
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact