Introduction: The concept of thermal safety distance upon laser activation has been recently introduced. We aimed to compare the thermal safety distance of Ho: YAG and thulium fiber laser (TFL) activation at different setups using an in vitro model. Methods: The experimental setup used a glass pipette with an open roof bulb in a 37 °C water bath to simulate a renal calyx. We analyzed two scenarios: (1) Laser activation without irrigation; (2) Laser activation at the center of the calyx with irrigation (saline at 40 cmH2O) via a flexible ureteroscope with a 12–14 Fr access sheath. Thermal camera tests were conducted using a Ho: YAG and TFL lasers. A thermal camera monitored the temperature for 60 s of laser activation at 5, 10, and 20 W, with and without irrigation. Each test was repeated three times. The Dewey and Sapareto formula was used to calculate cumulative equivalent minutes at 43 °C (CEM43), with a safety threshold of 120 min. The safety distance was defined as the minimum dist...
Ho: YAG and thulium fiber lasers exhibit comparable temperature distribution: an in vitro evaluation of thermal safety distances for endourological applications—section of EAU endourology
Saccomandi, Paola;
2025-01-01
Abstract
Introduction: The concept of thermal safety distance upon laser activation has been recently introduced. We aimed to compare the thermal safety distance of Ho: YAG and thulium fiber laser (TFL) activation at different setups using an in vitro model. Methods: The experimental setup used a glass pipette with an open roof bulb in a 37 °C water bath to simulate a renal calyx. We analyzed two scenarios: (1) Laser activation without irrigation; (2) Laser activation at the center of the calyx with irrigation (saline at 40 cmH2O) via a flexible ureteroscope with a 12–14 Fr access sheath. Thermal camera tests were conducted using a Ho: YAG and TFL lasers. A thermal camera monitored the temperature for 60 s of laser activation at 5, 10, and 20 W, with and without irrigation. Each test was repeated three times. The Dewey and Sapareto formula was used to calculate cumulative equivalent minutes at 43 °C (CEM43), with a safety threshold of 120 min. The safety distance was defined as the minimum dist...| File | Dimensione | Formato | |
|---|---|---|---|
|
s00345-025-05754-7.pdf
Accesso riservato
:
Publisher’s version
Dimensione
1.48 MB
Formato
Adobe PDF
|
1.48 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.