Introduction: The concept of thermal safety distance upon laser activation has been recently introduced. We aimed to compare the thermal safety distance of Ho: YAG and thulium fiber laser (TFL) activation at different setups using an in vitro model. Methods: The experimental setup used a glass pipette with an open roof bulb in a 37 °C water bath to simulate a renal calyx. We analyzed two scenarios: (1) Laser activation without irrigation; (2) Laser activation at the center of the calyx with irrigation (saline at 40 cmH2O) via a flexible ureteroscope with a 12–14 Fr access sheath. Thermal camera tests were conducted using a Ho: YAG and TFL lasers. A thermal camera monitored the temperature for 60 s of laser activation at 5, 10, and 20 W, with and without irrigation. Each test was repeated three times. The Dewey and Sapareto formula was used to calculate cumulative equivalent minutes at 43 °C (CEM43), with a safety threshold of 120 min. The safety distance was defined as the minimum dist...

Ho: YAG and thulium fiber lasers exhibit comparable temperature distribution: an in vitro evaluation of thermal safety distances for endourological applications—section of EAU endourology

Saccomandi, Paola;
2025-01-01

Abstract

Introduction: The concept of thermal safety distance upon laser activation has been recently introduced. We aimed to compare the thermal safety distance of Ho: YAG and thulium fiber laser (TFL) activation at different setups using an in vitro model. Methods: The experimental setup used a glass pipette with an open roof bulb in a 37 °C water bath to simulate a renal calyx. We analyzed two scenarios: (1) Laser activation without irrigation; (2) Laser activation at the center of the calyx with irrigation (saline at 40 cmH2O) via a flexible ureteroscope with a 12–14 Fr access sheath. Thermal camera tests were conducted using a Ho: YAG and TFL lasers. A thermal camera monitored the temperature for 60 s of laser activation at 5, 10, and 20 W, with and without irrigation. Each test was repeated three times. The Dewey and Sapareto formula was used to calculate cumulative equivalent minutes at 43 °C (CEM43), with a safety threshold of 120 min. The safety distance was defined as the minimum dist...
2025
In vitro model; Laser temperature; Stone; Thermal dose; Thermal safety;
In vitro model
Laser temperature
Stone
Thermal dose
Thermal safety
File in questo prodotto:
File Dimensione Formato  
s00345-025-05754-7.pdf

Accesso riservato

: Publisher’s version
Dimensione 1.48 MB
Formato Adobe PDF
1.48 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1294126
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact