In this work, the effects of different design features on the mechanical and biomechanical properties of Continuous Fiber-Reinforced (CFR) 3D printed prosthetic feet are investigated. It is discussed how this novel technology can offer opportunities to obtain tuneable characteristics of the prosthesis through the use of modular elements. The fiber-reinforced loops (FRL) are introduced as a design feature to locally reinforce the core of the prosthesis and affect its mechanical response. Eight prosthetic concepts, exploring different possible design solutions, are described and modelled using Finite Element simulations to evaluate their stiffness and Roll-over Shape (ROS). The results are compared with a reference commercial prosthesis (Proflex XC, & Ouml;ssur). The final concept is then 3D printed and characterized experimentally using standard mechanical testing according to PD ISO/TS 16955, with the addition of optoelectronic measurements to better evaluate local displacements of the...
Biomechanical and Displacement-Related Considerations in the Design of a 3D-Printed Composite Energy-Storage-and-Return Prosthetic Foot
Thahabi, Abdel Rahman Nedal Al;Martulli, Luca Michele;Bernasconi, Andrea;
2025-01-01
Abstract
In this work, the effects of different design features on the mechanical and biomechanical properties of Continuous Fiber-Reinforced (CFR) 3D printed prosthetic feet are investigated. It is discussed how this novel technology can offer opportunities to obtain tuneable characteristics of the prosthesis through the use of modular elements. The fiber-reinforced loops (FRL) are introduced as a design feature to locally reinforce the core of the prosthesis and affect its mechanical response. Eight prosthetic concepts, exploring different possible design solutions, are described and modelled using Finite Element simulations to evaluate their stiffness and Roll-over Shape (ROS). The results are compared with a reference commercial prosthesis (Proflex XC, & Ouml;ssur). The final concept is then 3D printed and characterized experimentally using standard mechanical testing according to PD ISO/TS 16955, with the addition of optoelectronic measurements to better evaluate local displacements of the...| File | Dimensione | Formato | |
|---|---|---|---|
|
Adv Materials Technologies - 2025 - Romanò - Biomechanical and Displacement‐Related Considerations in the Design of a.pdf
accesso aperto
Descrizione: Published paper
:
Publisher’s version
Dimensione
2.97 MB
Formato
Adobe PDF
|
2.97 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


