The sampling of odorous emissions is a fundamental step in correctly quantifying odour concentration. Its importance was strongly emphasized in the recent Italian legislation (MASE, 2023), which describes strict constraints for conducting olfactometric sampling. In particular, for point sources, it is necessary to assess the variability of the source to evaluate any spikes in emissivity and then sample consistently with the trend of this emissivity. Therefore, this study aims to conduct a field sampling campaign that meets the criteria mentioned in the Italian recent directive, combining olfactometric sampling with continuous monitoring of the source using portable PID instrumentation. The results obtained during this preliminary monitoring campaign highlight that the variability in VOC emissions is not strictly correlated with potential variability in terms of odour concentration. Indeed, despite the variations observed in continuous measuring at the source, the odour concentration measurements remained stable throughout the monitoring period. Chemical speciation of samples identified high concentrations of propene, varying in accordance with PID reading, while the odour potential was primarily due to lower concentrations of octene and nonene, which remained relatively constant. These results indicate that continuous monitoring emission variability does not necessarily translate into odour concentration variability.

Matching Continuous Monitoring and Bag Olfactometric Sampling at the Source: a Case Study

Innocente Giorgio;Polvara Elisa;Invernizzi Marzio;Sironi Selena
2024-01-01

Abstract

The sampling of odorous emissions is a fundamental step in correctly quantifying odour concentration. Its importance was strongly emphasized in the recent Italian legislation (MASE, 2023), which describes strict constraints for conducting olfactometric sampling. In particular, for point sources, it is necessary to assess the variability of the source to evaluate any spikes in emissivity and then sample consistently with the trend of this emissivity. Therefore, this study aims to conduct a field sampling campaign that meets the criteria mentioned in the Italian recent directive, combining olfactometric sampling with continuous monitoring of the source using portable PID instrumentation. The results obtained during this preliminary monitoring campaign highlight that the variability in VOC emissions is not strictly correlated with potential variability in terms of odour concentration. Indeed, despite the variations observed in continuous measuring at the source, the odour concentration measurements remained stable throughout the monitoring period. Chemical speciation of samples identified high concentrations of propene, varying in accordance with PID reading, while the odour potential was primarily due to lower concentrations of octene and nonene, which remained relatively constant. These results indicate that continuous monitoring emission variability does not necessarily translate into odour concentration variability.
2024
File in questo prodotto:
File Dimensione Formato  
2024_Innocente_Matching Continuous Monitoring and Bag Olfactometric Sampling at the Source a Case Study_CET.pdf

accesso aperto

: Publisher’s version
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1279802
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact