Recently, the interest in the Helmet interface during non-invasive respiratory support (NIRS) has increased due to the COVID-19 pandemic. During NIRS, positive end-expiratory pressure (PEEP) can be given as continuous positive airway pressure (CPAP), which maintains a positive airway pressure throughout the whole respiratory cycle with Helmet as an interface (H-CPAP). The main disadvantage of the H-CPAP is the inability to measure tidal volume (VT). Opto-electronic plethysmography (OEP) is a non-invasive technique that is not sensitive to gas compression/expansion inside the helmet. OEP acquisitions were performed on 28 healthy volunteers (14 females and 14 males) at baseline and during Helmet CPAP. The effect of posture (semi-recumbent vs. prone), flow (50 vs. 60 L/min), and PEEP (0 vs. 5 vs. 10 cmH2O) on the ventilatory and thoracic-abdominal pattern and the operational volumes were investigated. Prone position limited vital capacity, abdominal expansion and chest wall recruitment. A constant flow of 60 L/min reduced the need for the subject to ventilate while having a slight recruitment effect (100 mL) in the semi-recumbent position. A progressive increasing recruitment was found with higher PEEP but limited by the prone position. It is possible to accurately measure tidal volume during H-CPAP to deliver non-invasive ventilatory support using opto-electronic plethysmography during different clinical settings.

In Vivo Measurement of Tidal Volume During Non-invasive Respiratory Support by Continuous-Flow Helmet CPAP

Lo Mauro A.;Aliverti A.
2024-01-01

Abstract

Recently, the interest in the Helmet interface during non-invasive respiratory support (NIRS) has increased due to the COVID-19 pandemic. During NIRS, positive end-expiratory pressure (PEEP) can be given as continuous positive airway pressure (CPAP), which maintains a positive airway pressure throughout the whole respiratory cycle with Helmet as an interface (H-CPAP). The main disadvantage of the H-CPAP is the inability to measure tidal volume (VT). Opto-electronic plethysmography (OEP) is a non-invasive technique that is not sensitive to gas compression/expansion inside the helmet. OEP acquisitions were performed on 28 healthy volunteers (14 females and 14 males) at baseline and during Helmet CPAP. The effect of posture (semi-recumbent vs. prone), flow (50 vs. 60 L/min), and PEEP (0 vs. 5 vs. 10 cmH2O) on the ventilatory and thoracic-abdominal pattern and the operational volumes were investigated. Prone position limited vital capacity, abdominal expansion and chest wall recruitment. A constant flow of 60 L/min reduced the need for the subject to ventilate while having a slight recruitment effect (100 mL) in the semi-recumbent position. A progressive increasing recruitment was found with higher PEEP but limited by the prone position. It is possible to accurately measure tidal volume during H-CPAP to deliver non-invasive ventilatory support using opto-electronic plethysmography during different clinical settings.
2024
Flow
H-CPAP
Non-invasive respiratory support
Optoelectronic plethysmography
PEEP
Posture
Tidal volume
File in questo prodotto:
File Dimensione Formato  
LoMauroHELMETcpap.pdf

Accesso riservato

Dimensione 4.85 MB
Formato Adobe PDF
4.85 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1277990
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact