This paper focuses on the reliability of a synergistic procedure, involving dynamic tests complemented by documentary and architectural research, for the structural assessment of heritage towers. The reliability of the presented method is exemplified in a relevant case study, the Zuccaro's Tower in Mantua. As is known, historic buildings require addressed procedures in order to consider past building transformation and eventual damage/decay, which can affect the masonry properties and, more generally, the structural behavior. The proposed investigation procedure is based on multidisciplinary information (i.e., merging data) from historical and document studies, direct inspections, surveys of geometry and front surfaces, and dynamic tests in operational conditions. The processed information allowed the development and the calibration of a simplified numerical model, useful in driving the seismic/structural assessment of the tower. The results of past investigations, found during the archival research, contributed to the structural evaluation. This paper describes the main research outcomes and the model tuning with a special focus on the key role of the synergy between the applied methods for the assessment of a historic building.

Non-Destructive Testing and Synergistic Investigation of a Historic Tower

Saisi, Antonella;Borlenghi, Paolo;Gentile, Carmelo
2024-01-01

Abstract

This paper focuses on the reliability of a synergistic procedure, involving dynamic tests complemented by documentary and architectural research, for the structural assessment of heritage towers. The reliability of the presented method is exemplified in a relevant case study, the Zuccaro's Tower in Mantua. As is known, historic buildings require addressed procedures in order to consider past building transformation and eventual damage/decay, which can affect the masonry properties and, more generally, the structural behavior. The proposed investigation procedure is based on multidisciplinary information (i.e., merging data) from historical and document studies, direct inspections, surveys of geometry and front surfaces, and dynamic tests in operational conditions. The processed information allowed the development and the calibration of a simplified numerical model, useful in driving the seismic/structural assessment of the tower. The results of past investigations, found during the archival research, contributed to the structural evaluation. This paper describes the main research outcomes and the model tuning with a special focus on the key role of the synergy between the applied methods for the assessment of a historic building.
2024
historic tower
structural assessment
historical research
modelling
ambient vibration test
non-destructive testing
masonry
File in questo prodotto:
File Dimensione Formato  
buildings-14-01101.pdf

Accesso riservato

Descrizione: https://doi.org/10.3390/buildings14041101
: Publisher’s version
Dimensione 7.53 MB
Formato Adobe PDF
7.53 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1277334
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact