Doping is a common strategy in the field of semiconductor technology but its employment in organic photodetectors (OPDs) has been limited due to the typical uncontrollable increase of the dark currents. This study introduces three different molecular dopants, including p-type tris(pentafluorophenyl)borane, n-type benzyl viologen, and (4-(1,3-dimethyl-2,3-dihydro-1H-benzoimidazol-2-yl)-phenyl)dimethylamine, for near-infrared poly[[2,5-bis(2-hexyldecyl)-2,3,5,6-tetrahydro-3,6-dioxopyrrolo[3,4-c]pyrrole-1,4-diyl]-alt-[3′,3′′-dimethyl-2,2′:5′,2′′-terthiophene]-5,5′′-diyl]:[6,6]-phenyl C61butyric acid methyl ester (PMDPP3T:PC61BM) bulk-heterojunction OPDs. The results show that OPDs with optimal 0.02 wt% dopants exhibit low dark current (3.18 × 10−8A cm−2), high detectivity (5.56 × 1012Jones), and good environmental stability for ∼2 months. These doped OPDs are further used for pulse wave monitoring, which exhibit stable waveforms and can distinguish slow and fast heartbeat rates.

Molecular doping of near-infrared organic photodetectors for photoplethysmogram sensors

Scaccabarozzi A. D.;
2021-01-01

Abstract

Doping is a common strategy in the field of semiconductor technology but its employment in organic photodetectors (OPDs) has been limited due to the typical uncontrollable increase of the dark currents. This study introduces three different molecular dopants, including p-type tris(pentafluorophenyl)borane, n-type benzyl viologen, and (4-(1,3-dimethyl-2,3-dihydro-1H-benzoimidazol-2-yl)-phenyl)dimethylamine, for near-infrared poly[[2,5-bis(2-hexyldecyl)-2,3,5,6-tetrahydro-3,6-dioxopyrrolo[3,4-c]pyrrole-1,4-diyl]-alt-[3′,3′′-dimethyl-2,2′:5′,2′′-terthiophene]-5,5′′-diyl]:[6,6]-phenyl C61butyric acid methyl ester (PMDPP3T:PC61BM) bulk-heterojunction OPDs. The results show that OPDs with optimal 0.02 wt% dopants exhibit low dark current (3.18 × 10−8A cm−2), high detectivity (5.56 × 1012Jones), and good environmental stability for ∼2 months. These doped OPDs are further used for pulse wave monitoring, which exhibit stable waveforms and can distinguish slow and fast heartbeat rates.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1277174
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact