A 1+1D transient non-isothermal and multiphase polymer electrolyte membrane fuel cell model is developed. The model is validated on experimental data gathered on a segmented single cell and representative of a real-world automotive driving cycle, derived from the stack protocol defined in the ID-FAST H2020 project. During Low-Power operation, cell voltage response is mainly controlled by platinum oxide and water dynamics: the low hydration significantly affects cathode inlet performance. Throughout High-Power operation, instead, voltage transients are ascribable to local mass-transport related phenomena: in particular, liquid water accumulation along the channel strongly decreases the efficiency of cathode outlet region. Finally, the effect of relative humidity at cathode channel inlet is investigated: an increase in the humidification of the air inlet stream from 30% to 50% leads to a better proton conductivity and, therefore, to a significant enhancement of the performance of cathode inlet regions, which also means a slight improvement in the average stack efficiency from 62.2% to 62.8%. Lowering RH of the air-inlet stream from 30% to 15%, a worsening of proton conductivity is observed, which exacerbates performance heterogeneities and leads to a reduction of the average stack efficiency from 62.2% to 61.5%, consistently with experimental results.

Dynamic modeling of polymer electrolyte membrane fuel cells under real-world automotive driving cycle with experimental validation on segmented single cell

Verducci F.;Grimaldi A.;Colombo E.;Casalegno A.;Baricci A.
2024-01-01

Abstract

A 1+1D transient non-isothermal and multiphase polymer electrolyte membrane fuel cell model is developed. The model is validated on experimental data gathered on a segmented single cell and representative of a real-world automotive driving cycle, derived from the stack protocol defined in the ID-FAST H2020 project. During Low-Power operation, cell voltage response is mainly controlled by platinum oxide and water dynamics: the low hydration significantly affects cathode inlet performance. Throughout High-Power operation, instead, voltage transients are ascribable to local mass-transport related phenomena: in particular, liquid water accumulation along the channel strongly decreases the efficiency of cathode outlet region. Finally, the effect of relative humidity at cathode channel inlet is investigated: an increase in the humidification of the air inlet stream from 30% to 50% leads to a better proton conductivity and, therefore, to a significant enhancement of the performance of cathode inlet regions, which also means a slight improvement in the average stack efficiency from 62.2% to 62.8%. Lowering RH of the air-inlet stream from 30% to 15%, a worsening of proton conductivity is observed, which exacerbates performance heterogeneities and leads to a reduction of the average stack efficiency from 62.2% to 61.5%, consistently with experimental results.
2024
File in questo prodotto:
File Dimensione Formato  
Editor version 1-s2.0-S096014812401262X-main.pdf

accesso aperto

Descrizione: Manuscript
: Publisher’s version
Dimensione 9.01 MB
Formato Adobe PDF
9.01 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1275963
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact