A constant value of the Relative Biological Effectiveness (RBE), equal to 1.1, to weight the physical dose of proton therapy treatment planning collides with the experimental evidence of an increase of effectiveness along the depth dose profile, especially at the end of the particle range. In this context, it is desirable to develop new optimized treatment planning systems that account for a variable RBE when weighting the physical dose. In particular, due to the increasing interest on microdosimetry as a possible methodology for measuring physical quantities correlated with the biological effectiveness of the therapeutic beam, the development of new Tissue-Equivalent Proportional Counters (TEPCs) specifically designed for the clinical environment are in progress. In this framework, the silicon technology allows to produce solid state detectors of real micrometric dimensions. This is a valid alternative to the TEPC from a practical point of view, being simple, easy-of-use and more versatile. The feasibility of a solid state microdosimeter based on a monolithic double stage silicon telescope has been previously proposed and deeply investigated by comparing its response to the one obtained by reference TEPCs in various radiation fields. The device is constituted by a matrix of cylindrical elements, 2 μm in thickness and 9 μm in diameter, coupled to a single E stage, 500 μm in thickness. Each segmented ΔE stage acts as a solid state microdosimeter, while the E stage gives information on the energy of the impinging proton up to about 8 MeV. This work is dedicated to the description of the microdosimetric characterization of the 148 MeV energy-modulated proton beam at the radiobiological research line of the Trento Proton Therapy Centre by means of a pixelated silicon microdosimeter. All measurements were carried out at different positions across the spread-out Bragg peak (SOBP) and the corresponding microdosimetric distributions were derived by applying a novel extrapolation algorithm. Finally, microdosimetric assessment of Relative Biological Effectiveness was carried out by weighting the dose distribution of the lineal energy with the Loncol's biological weighting function. Benefits and possible limitations of this approach are discussed.

Solid state microdosimetry of a 148 MeV proton spread-out Bragg peak with a pixelated silicon telescope

Bortot D.;Mazzucconi D.;Pola A.;Agosteo S.
2024-01-01

Abstract

A constant value of the Relative Biological Effectiveness (RBE), equal to 1.1, to weight the physical dose of proton therapy treatment planning collides with the experimental evidence of an increase of effectiveness along the depth dose profile, especially at the end of the particle range. In this context, it is desirable to develop new optimized treatment planning systems that account for a variable RBE when weighting the physical dose. In particular, due to the increasing interest on microdosimetry as a possible methodology for measuring physical quantities correlated with the biological effectiveness of the therapeutic beam, the development of new Tissue-Equivalent Proportional Counters (TEPCs) specifically designed for the clinical environment are in progress. In this framework, the silicon technology allows to produce solid state detectors of real micrometric dimensions. This is a valid alternative to the TEPC from a practical point of view, being simple, easy-of-use and more versatile. The feasibility of a solid state microdosimeter based on a monolithic double stage silicon telescope has been previously proposed and deeply investigated by comparing its response to the one obtained by reference TEPCs in various radiation fields. The device is constituted by a matrix of cylindrical elements, 2 μm in thickness and 9 μm in diameter, coupled to a single E stage, 500 μm in thickness. Each segmented ΔE stage acts as a solid state microdosimeter, while the E stage gives information on the energy of the impinging proton up to about 8 MeV. This work is dedicated to the description of the microdosimetric characterization of the 148 MeV energy-modulated proton beam at the radiobiological research line of the Trento Proton Therapy Centre by means of a pixelated silicon microdosimeter. All measurements were carried out at different positions across the spread-out Bragg peak (SOBP) and the corresponding microdosimetric distributions were derived by applying a novel extrapolation algorithm. Finally, microdosimetric assessment of Relative Biological Effectiveness was carried out by weighting the dose distribution of the lineal energy with the Loncol's biological weighting function. Benefits and possible limitations of this approach are discussed.
2024
Extrapolation algorithm
Microdosimetry
Proton RBE
Proton therapy
Silicon telescope
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1350448724001689-main.pdf

accesso aperto

: Publisher’s version
Dimensione 6.46 MB
Formato Adobe PDF
6.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1269130
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact