A hybrid field model (HFM) based on the combination of magnetic equivalent circuit (MEC) and exact conformal mapping (ECM) is developed to calculate the open-circuit field of interior permanent-magnet (IPM) motor. In the proposed HFM, the IPM and iron saturations are transformed into equivalent current on the rotor surface and stator bore. ECM can calculate the air-gap field analytically using the equivalent current. Once the air-gap field is obtained, the MEC in the iron region can be solved and gives the new value of equivalent current, which forms a calculation loop. Hence, iterative solving process is required to determine the equivalent current and iron permeability in the rotor and stator. In order to verify the proposed model, both finite-element (FE) analysis and experiment are performed on IPM motors with V-type rotor and conventional "-" type rotor. Their results demonstrate the high accuracy of HFM.

Open-Circuit Field Prediction of Interior Permanent-Magnet Motor Using Hybrid Field Model Accounting for Saturation

Li, Zhaokai;
2019-01-01

Abstract

A hybrid field model (HFM) based on the combination of magnetic equivalent circuit (MEC) and exact conformal mapping (ECM) is developed to calculate the open-circuit field of interior permanent-magnet (IPM) motor. In the proposed HFM, the IPM and iron saturations are transformed into equivalent current on the rotor surface and stator bore. ECM can calculate the air-gap field analytically using the equivalent current. Once the air-gap field is obtained, the MEC in the iron region can be solved and gives the new value of equivalent current, which forms a calculation loop. Hence, iterative solving process is required to determine the equivalent current and iron permeability in the rotor and stator. In order to verify the proposed model, both finite-element (FE) analysis and experiment are performed on IPM motors with V-type rotor and conventional "-" type rotor. Their results demonstrate the high accuracy of HFM.
2019
Complex permeance
interior permanent magnet machine
magnetic equivalent circuit
saturation effect
File in questo prodotto:
File Dimensione Formato  
Final Submission2.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 698.59 kB
Formato Adobe PDF
698.59 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1268588
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 11
social impact