The study presents the development of a structural monitoring system installed in a 45-m-high steel wind tower located in Italy. The installed monitoring system was composed by 16 strain gauges placed in the tower wall, in a pattern of four Wheatstone bridges at 45°, together with thermal couples, at 21 m from the ground (half-height of the tower). Moreover, several accelerometers were placed along the tower height (with one of them located next to the strain gauges). The wind velocity and directions were obtained directly from the turbine own monitoring system. Such a monitoring system was designed because, due to the decrement of the total height from the original design, the tower sufers from resonance problems. In fact, the investigated tower was originally designed with 65 m of height but then, to comply with local regulations, the height was decreased to the actual size. Therefore, to allow safe operation and avoid excessive fatigue due to the increased displacements, the velocity of the rotor has been manually limited causing an important reduction in the energy production. The results of the study show the importance of monitoring the resonance issue. The diferences between the damage indexes obtained with two diferent working conditions are discussed: tower working with limited operational capacity and tower working at its maximum capacity (in resonance).

Structural health monitoring of an onshore steel wind turbine

M. Simoncelli;
2024-01-01

Abstract

The study presents the development of a structural monitoring system installed in a 45-m-high steel wind tower located in Italy. The installed monitoring system was composed by 16 strain gauges placed in the tower wall, in a pattern of four Wheatstone bridges at 45°, together with thermal couples, at 21 m from the ground (half-height of the tower). Moreover, several accelerometers were placed along the tower height (with one of them located next to the strain gauges). The wind velocity and directions were obtained directly from the turbine own monitoring system. Such a monitoring system was designed because, due to the decrement of the total height from the original design, the tower sufers from resonance problems. In fact, the investigated tower was originally designed with 65 m of height but then, to comply with local regulations, the height was decreased to the actual size. Therefore, to allow safe operation and avoid excessive fatigue due to the increased displacements, the velocity of the rotor has been manually limited causing an important reduction in the energy production. The results of the study show the importance of monitoring the resonance issue. The diferences between the damage indexes obtained with two diferent working conditions are discussed: tower working with limited operational capacity and tower working at its maximum capacity (in resonance).
2024
File in questo prodotto:
File Dimensione Formato  
s13349-024-00794-w (1).pdf

accesso aperto

: Publisher’s version
Dimensione 3.51 MB
Formato Adobe PDF
3.51 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1265342
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact