Tendons and ligaments play an important role to ensure mobility and stability. To correctly understand the characteristics of these fibrous collagenous connective tissues, it is fundamental to highlight their 3D microstructure. In this study a microtomography (microCT) system was used to acquire human hamstring tendons after performing specific preparations to enhance image contrast. Specifically, samples were treated either through chemical dehydration or by 2% of phosphotungstic acid (PTA) in water (H2O) or in 70% ethanol (EtOH) solution. Acquired images were elaborated using dedicated techniques based on 3D Hessian multiscale filter so as to highlight the fibrous structure and identify specific geometric features. For any strategy of sample preparation, the proposed approach resulted to be adequate for identifying fascicle features, thus obtaining structures with diameter in the range of 100-600 μm and proper longitudinal alignment. In conclusion, a novel contrast enhancement microCT protocol was designed and preliminarily validated for the microstructural analysis of fibrous tissues.

Contrast-Enhanced Microtomography For Volumetric Analysis Of Microstructure In Ligaments And Tendons

Lopomo N. F.
2023-01-01

Abstract

Tendons and ligaments play an important role to ensure mobility and stability. To correctly understand the characteristics of these fibrous collagenous connective tissues, it is fundamental to highlight their 3D microstructure. In this study a microtomography (microCT) system was used to acquire human hamstring tendons after performing specific preparations to enhance image contrast. Specifically, samples were treated either through chemical dehydration or by 2% of phosphotungstic acid (PTA) in water (H2O) or in 70% ethanol (EtOH) solution. Acquired images were elaborated using dedicated techniques based on 3D Hessian multiscale filter so as to highlight the fibrous structure and identify specific geometric features. For any strategy of sample preparation, the proposed approach resulted to be adequate for identifying fascicle features, thus obtaining structures with diameter in the range of 100-600 μm and proper longitudinal alignment. In conclusion, a novel contrast enhancement microCT protocol was designed and preliminarily validated for the microstructural analysis of fibrous tissues.
2023
File in questo prodotto:
File Dimensione Formato  
Bushara2023_JMMB.pdf

Accesso riservato

: Publisher’s version
Dimensione 4.9 MB
Formato Adobe PDF
4.9 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1263766
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact