: This study was aimed at analyzing the effectiveness of ultrasonography (US) and ultrasound elastography (UE) in evaluating longitudinal sliding and stiffness of nerves. In line with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, we analyzed 1112 publications (range: 2010-2021) extracted from MEDLINE, Scopus and Web of Science focusing on specific outcomes, including shear wave velocity (m/s), shear modulus (kPa), strain ratio (SR) and excursion (mm). Thirty-three papers were included and evaluated for overall quality and risk of bias. From the analysis of data concerning 1435 participants, mean shear wave velocity (SWV) in the sciatic nerve was 6.70 ± 1.26 m/s in controls and 7.51 ± 1.73 m/s in participants presenting with leg pain; in the tibial nerve, mean SWV was 3.83 ± 0.33 m/s in controls and 3.42 ± 3.53 m/s in participants presenting with diabetic peripheral neuropathy (DPN). The mean shear modulus (SM) was 20.9 ± 9.33 kPa for sciatic nerve, whereas it was an average of 23.3 ± 7.20 kPa for the tibial nerve. Considering 146 subjects (78 experimental, 68 controls) no significant difference was observed in SWV when comparing participants with DPN with controls (standard mean difference [SMD]: 1.26, 95% confidence interval [CI]: 0.54, 1.97), whereas a significant difference was observed in the SM (SMD: 1.78, 95% CI: 1.32, 2.25); furthermore, we found significant differences between left and right extremity nerves (SMD:1.14. 95% CI: 0.45, 1.83) among 458 participants (270 with DPN and 188 controls). No descriptive statistics are available for excursion because of the variability in participants and limb positions, whereas SR is considered only a semiquantitative outcome and therefore not comparable among different studies. Despite the presence of some limitations in study designs and methodological biases, on the basis of our findings, we can conclude that US and UE are effective methods in assessing longitudinal sliding and stiffness of lower extremity nerves in both symptomatic and asymptomatic subjects.

Longitudinal Movements and Stiffness of Lower Extremity Nerves Measured by Ultrasonography and Ultrasound Elastography in Symptomatic and Asymptomatic Populations: A Systematic Review With Meta-analysis

Lopomo N. F.;
2023-01-01

Abstract

: This study was aimed at analyzing the effectiveness of ultrasonography (US) and ultrasound elastography (UE) in evaluating longitudinal sliding and stiffness of nerves. In line with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, we analyzed 1112 publications (range: 2010-2021) extracted from MEDLINE, Scopus and Web of Science focusing on specific outcomes, including shear wave velocity (m/s), shear modulus (kPa), strain ratio (SR) and excursion (mm). Thirty-three papers were included and evaluated for overall quality and risk of bias. From the analysis of data concerning 1435 participants, mean shear wave velocity (SWV) in the sciatic nerve was 6.70 ± 1.26 m/s in controls and 7.51 ± 1.73 m/s in participants presenting with leg pain; in the tibial nerve, mean SWV was 3.83 ± 0.33 m/s in controls and 3.42 ± 3.53 m/s in participants presenting with diabetic peripheral neuropathy (DPN). The mean shear modulus (SM) was 20.9 ± 9.33 kPa for sciatic nerve, whereas it was an average of 23.3 ± 7.20 kPa for the tibial nerve. Considering 146 subjects (78 experimental, 68 controls) no significant difference was observed in SWV when comparing participants with DPN with controls (standard mean difference [SMD]: 1.26, 95% confidence interval [CI]: 0.54, 1.97), whereas a significant difference was observed in the SM (SMD: 1.78, 95% CI: 1.32, 2.25); furthermore, we found significant differences between left and right extremity nerves (SMD:1.14. 95% CI: 0.45, 1.83) among 458 participants (270 with DPN and 188 controls). No descriptive statistics are available for excursion because of the variability in participants and limb positions, whereas SR is considered only a semiquantitative outcome and therefore not comparable among different studies. Despite the presence of some limitations in study designs and methodological biases, on the basis of our findings, we can conclude that US and UE are effective methods in assessing longitudinal sliding and stiffness of lower extremity nerves in both symptomatic and asymptomatic subjects.
2023
Nerve excursion
Nerve stiffness
Shear wave elastography
Shear wave modulus
Strain
Ultrasonography
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0301562923001400-main.pdf

Accesso riservato

: Publisher’s version
Dimensione 2.31 MB
Formato Adobe PDF
2.31 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1263715
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact