This paper presents a study on cold microdrawing of pure magnesium for biomedical applications, where hollow sinking drawing of microtubes of 820 lm diameter and wall thickness around 100 lm was used, varying drawing speeds to achieve a significant reduction in cross-sectional area in a single pass. Results showed an improved surface finish with reduced surface roughness after drawing. The material exhibited an increase in microhardness and ultimate tensile strength by 41% due to work hardening caused by plastic deformation. The study also identified wall thickening of the tube and observed springback behavior of Mg at the die exit. Drawing forces were collected for process monitoring, and finite element (FE) simulations were conducted to assess the risk of pure Mg microtube breakage. This research contributes to advancing the state of the art in Mg microtube drawing, addressing the unique challenge of working with such small tube dimensions where limited studies currently exist.

Cold Microdrawing of Pure Magnesium Capillary Structures for Biomedical Applications

Pizzi M.;De Gaetano F.;Arleo F.;Boschetti F.;Strano M.;Annoni M.
2023-01-01

Abstract

This paper presents a study on cold microdrawing of pure magnesium for biomedical applications, where hollow sinking drawing of microtubes of 820 lm diameter and wall thickness around 100 lm was used, varying drawing speeds to achieve a significant reduction in cross-sectional area in a single pass. Results showed an improved surface finish with reduced surface roughness after drawing. The material exhibited an increase in microhardness and ultimate tensile strength by 41% due to work hardening caused by plastic deformation. The study also identified wall thickening of the tube and observed springback behavior of Mg at the die exit. Drawing forces were collected for process monitoring, and finite element (FE) simulations were conducted to assess the risk of pure Mg microtube breakage. This research contributes to advancing the state of the art in Mg microtube drawing, addressing the unique challenge of working with such small tube dimensions where limited studies currently exist.
2023
biomedical devices
cold drawing
hollow sinking
magnesium
microtubes
File in questo prodotto:
File Dimensione Formato  
Cold Microdrawing of Pure Magnesium Capillary Structures for Biomedical Applications.pdf

Accesso riservato

: Publisher’s version
Dimensione 1.79 MB
Formato Adobe PDF
1.79 MB Adobe PDF   Visualizza/Apri
0Cold Microdrawing of Pure Magnesium Capillary Structures for Biomedical Applications.pdf

embargo fino al 11/01/2025

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1260518
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact