BACKGROUND: In asymptomatic carotid stenosis (ACS), different plaque types, i.e. lipidic (LP), fibrous (FP), and calcific (CP), could have different hemodynamic and structural behaviors.METHODS: Different carotid plaques, reconstructed from medical imaging of ACS >70%, were analyzed by computing fluid structure interac-tion (FSI), modeling the spatial distribution of wall shear stresses (WSS), plaque displacements (D), von Mises stresses (VMS), and absorbed elastic energy (AEE) together with their maximum-in-space values at the systole (WSSsyst , Dsyst , VMSsyst andAEEsyst). RESULTS: WSS resulted significantly higher in CP, whereas D and VMS showed the highest values for LP. Regarding AEEsyst stored by the plaques, LP absorbed in average 2320 J/m3 , FP 408 J/m3 (470%) and CP 99 J/m3 (2240%), (P<0.01, P<0.01, and P<0.01, respectively). CONCLUSIONS: Depending upon their nature, plaques store different deformations and inner distributions of forces, thus potentially influenc-ing their vulnerability.

Fluid structure interaction analysis to stratify the behavior of different atheromatous carotid plaques

Vergara C.;
2023-01-01

Abstract

BACKGROUND: In asymptomatic carotid stenosis (ACS), different plaque types, i.e. lipidic (LP), fibrous (FP), and calcific (CP), could have different hemodynamic and structural behaviors.METHODS: Different carotid plaques, reconstructed from medical imaging of ACS >70%, were analyzed by computing fluid structure interac-tion (FSI), modeling the spatial distribution of wall shear stresses (WSS), plaque displacements (D), von Mises stresses (VMS), and absorbed elastic energy (AEE) together with their maximum-in-space values at the systole (WSSsyst , Dsyst , VMSsyst andAEEsyst). RESULTS: WSS resulted significantly higher in CP, whereas D and VMS showed the highest values for LP. Regarding AEEsyst stored by the plaques, LP absorbed in average 2320 J/m3 , FP 408 J/m3 (470%) and CP 99 J/m3 (2240%), (P<0.01, P<0.01, and P<0.01, respectively). CONCLUSIONS: Depending upon their nature, plaques store different deformations and inner distributions of forces, thus potentially influenc-ing their vulnerability.
2023
File in questo prodotto:
File Dimensione Formato  
carotid-FSI-JCS-2022.pdf

Accesso riservato

Dimensione 3.42 MB
Formato Adobe PDF
3.42 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1250125
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact