The transportation industry now accounts for approximately a quarter of worldwide energy-related direct CO2 emissions, and governments all around the globe have committed to converting their fossil-fuel vehicles to zero-emission ones by adopting electric vehicles. Current electric vehicles (EV) can store approximately 18 to 100 kWh of energy, which may be employed not only for commuting but also for other purposes such as delivering energy to households (V2H) or buildings (V2B), as well as offering ancillary services to the power grid (V2G). In this study, a real test setting including a trending bidirectional charger, an EV, a PV simulator, and household appliances are utilized to evaluate the performance of various V2H components and to learn about the concerns that may arise during V2H operation. The results of the tests on the bidirectional EV charger are presented in this paper. Although the results of the tests on the charger installed in the house are not satisfactory and consistent to the project’s goal, they are released in order to aid future studies in better understanding the true challenges of commercial bidirectional chargers.

Are Commercial EV Chargers Ready to Aid with Household Power Consumption?

Shams Ashkezari L.;Succetti M.;Brenna M.
2023-01-01

Abstract

The transportation industry now accounts for approximately a quarter of worldwide energy-related direct CO2 emissions, and governments all around the globe have committed to converting their fossil-fuel vehicles to zero-emission ones by adopting electric vehicles. Current electric vehicles (EV) can store approximately 18 to 100 kWh of energy, which may be employed not only for commuting but also for other purposes such as delivering energy to households (V2H) or buildings (V2B), as well as offering ancillary services to the power grid (V2G). In this study, a real test setting including a trending bidirectional charger, an EV, a PV simulator, and household appliances are utilized to evaluate the performance of various V2H components and to learn about the concerns that may arise during V2H operation. The results of the tests on the bidirectional EV charger are presented in this paper. Although the results of the tests on the charger installed in the house are not satisfactory and consistent to the project’s goal, they are released in order to aid future studies in better understanding the true challenges of commercial bidirectional chargers.
2023
bidirectional charger
constant tariff
electric vehicle (EV)
energy management system (EMS)
nearly zero energy building (NZEB)
time varying tariff
vehicle to home (V2H)
File in questo prodotto:
File Dimensione Formato  
electronics-12-02065-v3.pdf

accesso aperto

Dimensione 8.53 MB
Formato Adobe PDF
8.53 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1248722
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact