Single-switch quasi-resonant DC inverters are preferred in low-power induction-heating applications for their cheapness. However, they pose difficulties in enforcing soft-switching and show limited controllability. A good design of these converters must proceed in parallel with the characterization of the load and the operating conditions. The control of the switching frequency has a critical relationship to the non-linear behavior of the load due to electro-thermal coupling and geometrical anisotropies. Finite element methods enable the analysis of this kind of multiphysics coupled systems, but the simulation of transient dynamics is computationally expensive. The goal of this article is to propose a time-domain simulation strategy to analyze the behavior of induction heating systems with a quasi-resonant single-ended DC inverter using pulse frequency modulation and variable load. The load behavior is estimated through frequency stationary analysis and integrated into the time-domain simulations as a non-linear equivalent impedance parametrized by look-up tables. The model considers variations in temperature dynamics, the presence of work-piece anisotropies, and current harmonic waveforms. The power regulation strategy based on the control of the switch turn-on time is tested in a case study with varying load and it is shown that it is able to maintain the converter in the safe operation region, handling variations up to of (Formula presented.) in the equivalent load resistance.

Modelling and Simulation of Quasi-Resonant Inverter for Induction Heating under Variable Load

Spateri E.;Fredy Ruiz;Gruosso G.
2023-01-01

Abstract

Single-switch quasi-resonant DC inverters are preferred in low-power induction-heating applications for their cheapness. However, they pose difficulties in enforcing soft-switching and show limited controllability. A good design of these converters must proceed in parallel with the characterization of the load and the operating conditions. The control of the switching frequency has a critical relationship to the non-linear behavior of the load due to electro-thermal coupling and geometrical anisotropies. Finite element methods enable the analysis of this kind of multiphysics coupled systems, but the simulation of transient dynamics is computationally expensive. The goal of this article is to propose a time-domain simulation strategy to analyze the behavior of induction heating systems with a quasi-resonant single-ended DC inverter using pulse frequency modulation and variable load. The load behavior is estimated through frequency stationary analysis and integrated into the time-domain simulations as a non-linear equivalent impedance parametrized by look-up tables. The model considers variations in temperature dynamics, the presence of work-piece anisotropies, and current harmonic waveforms. The power regulation strategy based on the control of the switch turn-on time is tested in a case study with varying load and it is shown that it is able to maintain the converter in the safe operation region, handling variations up to of (Formula presented.) in the equivalent load resistance.
2023
circuital equivalent
electrical converters
electro-thermal system
induction heating
multiphysics modelling
File in questo prodotto:
File Dimensione Formato  
electronics-12-00753.pdf

accesso aperto

Descrizione: articolo
: Publisher’s version
Dimensione 1.26 MB
Formato Adobe PDF
1.26 MB Adobe PDF Visualizza/Apri