Background and objective: Mechanical thrombectomy is a minimally invasive procedure that aims at re-moving the occluding thrombus from the vasculature of acute ischemic stroke patients. Thrombectomy success and failure can be studied using in-silico thrombectomy models. Such models require realistic modeling steps to be effective. We here present a new approach to model microcatheter tracking during thrombectomy.Methods: For 3 patient-specific vessel geometries, we performed finite-element simulations of the micro-catheter tracking (1) following the vessel centerline (centerline method) and (2) as a one-step insertion simulation, where the microcatheter tip was advanced along the vessel centerline while its body was free to interact with the vessel wall (tip-dragging method). Qualitative validation of the two tracking methods was performed with the patient's digital subtraction angiography (DSA) images. In addition, we com-pared simulated thrombectomy outcomes (successful vs unsuccessful thrombus retrieval) and maximum principal stresses on the thrombus between the centerline and tip-dragging method.Results: Qualitative comparison with the DSA images showed that the tip-dragging method more realisti-cally resembles the patient-specific microcatheter-tracking scenario, where the microcatheter approaches the vessel walls. Although the simulated thrombectomy outcomes were similar in terms of thrombus retrieval, the thrombus stress fields (and the associated fragmentation of the thrombus) were strongly different between the two methods, with local differences in the maximum principal stress curves up to 84%.Conclusions: Microcatheter positioning with respect to the vessel affects the stress fields of the thrombus during retrieval, and therefore, may influence thrombus fragmentation and retrieval in-silico thrombec-tomy.(c) 2023 Elsevier B.V. All rights reserved.

Microcatheter tracking in thrombectomy procedures: A finite-element simulation study

Bridio, S;Rodriguez Matas, JF;Dubini, G;Migliavacca, F;Luraghi, G
2023-01-01

Abstract

Background and objective: Mechanical thrombectomy is a minimally invasive procedure that aims at re-moving the occluding thrombus from the vasculature of acute ischemic stroke patients. Thrombectomy success and failure can be studied using in-silico thrombectomy models. Such models require realistic modeling steps to be effective. We here present a new approach to model microcatheter tracking during thrombectomy.Methods: For 3 patient-specific vessel geometries, we performed finite-element simulations of the micro-catheter tracking (1) following the vessel centerline (centerline method) and (2) as a one-step insertion simulation, where the microcatheter tip was advanced along the vessel centerline while its body was free to interact with the vessel wall (tip-dragging method). Qualitative validation of the two tracking methods was performed with the patient's digital subtraction angiography (DSA) images. In addition, we com-pared simulated thrombectomy outcomes (successful vs unsuccessful thrombus retrieval) and maximum principal stresses on the thrombus between the centerline and tip-dragging method.Results: Qualitative comparison with the DSA images showed that the tip-dragging method more realisti-cally resembles the patient-specific microcatheter-tracking scenario, where the microcatheter approaches the vessel walls. Although the simulated thrombectomy outcomes were similar in terms of thrombus retrieval, the thrombus stress fields (and the associated fragmentation of the thrombus) were strongly different between the two methods, with local differences in the maximum principal stress curves up to 84%.Conclusions: Microcatheter positioning with respect to the vessel affects the stress fields of the thrombus during retrieval, and therefore, may influence thrombus fragmentation and retrieval in-silico thrombec-tomy.(c) 2023 Elsevier B.V. All rights reserved.
2023
Thrombectomy
Acute ischemic stroke
Stent-retriever
Finite element analysis
File in questo prodotto:
File Dimensione Formato  
Arrarte Terreros_2023.pdf

embargo fino al 01/05/2024

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1236963
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact