This study aims at presenting the experimental and numerical assessment of a novel dissipative connection system (DCS) designed to improve the seismic performance of prefabricated sheds. The device, which is placed on the top of columns, exploits the movement of a rigid slider on a sloped surface to dissipate seismic energy and control the lateral displacement of the beam, and to provide a recentering effect at the end of the earthquake. The backbone curve of the DCS, and the effect of vertical load and sliding velocity were assessed in experimental tests conducted on a scaled prototype, according to a test protocol designed accounting for similarity requirements. In the second part of the study, non-linear dynamic analyses were performed on a finite element model of a portal frame implementing, at beam-column joints, either the DCS or a pure friction connection. The results highlighted the effectiveness of the DCS in controlling beam-to-column displacements, reducing shear forces on the top of columns, and limiting residual displacements that can accrue during ground motion sequences.

Seismic retrofitting of RC precast industrial sheds: experimental characterization and numerical case study

C. Pettorruso;E. Bruschi;V. Quaglini
2022-01-01

Abstract

This study aims at presenting the experimental and numerical assessment of a novel dissipative connection system (DCS) designed to improve the seismic performance of prefabricated sheds. The device, which is placed on the top of columns, exploits the movement of a rigid slider on a sloped surface to dissipate seismic energy and control the lateral displacement of the beam, and to provide a recentering effect at the end of the earthquake. The backbone curve of the DCS, and the effect of vertical load and sliding velocity were assessed in experimental tests conducted on a scaled prototype, according to a test protocol designed accounting for similarity requirements. In the second part of the study, non-linear dynamic analyses were performed on a finite element model of a portal frame implementing, at beam-column joints, either the DCS or a pure friction connection. The results highlighted the effectiveness of the DCS in controlling beam-to-column displacements, reducing shear forces on the top of columns, and limiting residual displacements that can accrue during ground motion sequences.
2022
Proceedings of the Third European Conference on Earthquake Engineering and Seismology – 3ECEES
9789731005331
prefabricated sheds
energy dissipation
seismic retrofit
beam-to-column connection
recentering
File in questo prodotto:
File Dimensione Formato  
Mari_3ECCES.pdf

Accesso riservato

Descrizione: Articolo Principale
: Publisher’s version
Dimensione 872.53 kB
Formato Adobe PDF
872.53 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1233510
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact