Algae-bacteria (AB) consortia can be exploited for effective wastewater treatment, based on photosynthetic oxygenation to reduce energy requirements for aeration. While algal kinetics have been extensively evaluated, bacterial kinetics in AB systems are still based on parameters taken from the activated sludge models, lacking an experimental validation for AB consortia. A respirometric procedure was therefore proposed, to estimate bacterial kinetics in both activated sludge and AB, under different conditions of temperature, pH, dissolved oxygen, and substrate availability. Bacterial activities were differently influenced by operational/environmental conditions, suggesting that the adoption of typical activated sludge parameters could be inadequate for AB modelling. Indeed, respirometric results show that bacteria in AB consortia were adapted to a wider range of conditions, compared to activated sludge, confirming that a dedicated calibration of bacterial kinetics is essential for effectively modelling AB systems, and respirometry was proven to be a powerful and reliable tool to this purpose.

Respirometric assessment of bacterial kinetics in algae-bacteria and activated sludge processes

Rossi S.;Ficara E.
2022-01-01

Abstract

Algae-bacteria (AB) consortia can be exploited for effective wastewater treatment, based on photosynthetic oxygenation to reduce energy requirements for aeration. While algal kinetics have been extensively evaluated, bacterial kinetics in AB systems are still based on parameters taken from the activated sludge models, lacking an experimental validation for AB consortia. A respirometric procedure was therefore proposed, to estimate bacterial kinetics in both activated sludge and AB, under different conditions of temperature, pH, dissolved oxygen, and substrate availability. Bacterial activities were differently influenced by operational/environmental conditions, suggesting that the adoption of typical activated sludge parameters could be inadequate for AB modelling. Indeed, respirometric results show that bacteria in AB consortia were adapted to a wider range of conditions, compared to activated sludge, confirming that a dedicated calibration of bacterial kinetics is essential for effectively modelling AB systems, and respirometry was proven to be a powerful and reliable tool to this purpose.
2022
Activated sludge
Kinetics
Mathematical modelling
Microalgae-bacteria consortia
Respirometry
Wastewater treatment
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S096085242200445X-main.pdf

accesso aperto

: Publisher’s version
Dimensione 2.29 MB
Formato Adobe PDF
2.29 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1233336
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 5
social impact