Background and objective: In patients with suspected Coronary Artery Disease (CAD), the severity of stenosis needs to be assessed for precise clinical management. An automatic deep learning-based algorithm to classify coronary stenosis lesions according to the Coronary Artery Disease Reporting and Data System (CAD-RADS) in multiplanar reconstruction images acquired with Coronary Computed Tomography Angiography (CCTA) is proposed. Methods: In this retrospective study, 288 patients with suspected CAD who underwent CCTA scans were included. To model long-range semantic information, which is needed to identify and classify stenosis with challenging appearance, we adopted a token-mixer architecture (ConvMixer), which can learn structural relationship over the whole coronary artery. ConvMixer consists of a patch embedding layer followed by repeated convolutional blocks to enable the algorithm to learn long-range dependences between pixels. To visually assess ConvMixer performance, Gradient-Weighted Class Activation Mapping (Grad-CAM) analysis was used. Results: Experimental results using 5-fold cross-validation showed that our ConvMixer can classify significant coronary artery stenosis (i.e., stenosis with luminal narrowing ≥50%) with accuracy and sensitivity of 87% and 90%, respectively. For CAD-RADS 0 vs. 1–2 vs. 3–4 vs. 5 classification, ConvMixer achieved accuracy and sensitivity of 72% and 75%, respectively. Additional experiments showed that ConvMixer achieved a better trade-off between performance and complexity compared to pyramid-shaped convolutional neural networks. Conclusions: Our algorithm might provide clinicians with decision support, potentially reducing the interobserver variability for coronary artery stenosis evaluation.

A token-mixer architecture for CAD-RADS classification of coronary stenosis on multiplanar reconstruction CT images

Caiani E. G.;
2023-01-01

Abstract

Background and objective: In patients with suspected Coronary Artery Disease (CAD), the severity of stenosis needs to be assessed for precise clinical management. An automatic deep learning-based algorithm to classify coronary stenosis lesions according to the Coronary Artery Disease Reporting and Data System (CAD-RADS) in multiplanar reconstruction images acquired with Coronary Computed Tomography Angiography (CCTA) is proposed. Methods: In this retrospective study, 288 patients with suspected CAD who underwent CCTA scans were included. To model long-range semantic information, which is needed to identify and classify stenosis with challenging appearance, we adopted a token-mixer architecture (ConvMixer), which can learn structural relationship over the whole coronary artery. ConvMixer consists of a patch embedding layer followed by repeated convolutional blocks to enable the algorithm to learn long-range dependences between pixels. To visually assess ConvMixer performance, Gradient-Weighted Class Activation Mapping (Grad-CAM) analysis was used. Results: Experimental results using 5-fold cross-validation showed that our ConvMixer can classify significant coronary artery stenosis (i.e., stenosis with luminal narrowing ≥50%) with accuracy and sensitivity of 87% and 90%, respectively. For CAD-RADS 0 vs. 1–2 vs. 3–4 vs. 5 classification, ConvMixer achieved accuracy and sensitivity of 72% and 75%, respectively. Additional experiments showed that ConvMixer achieved a better trade-off between performance and complexity compared to pyramid-shaped convolutional neural networks. Conclusions: Our algorithm might provide clinicians with decision support, potentially reducing the interobserver variability for coronary artery stenosis evaluation.
2023
CAD-RADS
ConvMixer
Coronary artery disease
Coronary CT angiography
Deep learning
Stenosis classification
Token-Mixer architecture
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0010482522011921-main.pdf

accesso aperto

: Publisher’s version
Dimensione 4.15 MB
Formato Adobe PDF
4.15 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1231276
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 2
social impact