The present paper explores the utilisation of dopants to increase the critical temperature of Carbon Dioxide (sCO(2)) as a solution towards maintaining the high thermal efficiencies of sCO(2) cycles even when ambient temperatures compromise their feasibility. To this end, the impact of adopting CO2-based mixtures on the performance of power blocks representative of Concentrated Solar Power plants is explored, considering two possible dopants: hexafluorobenzene (C6F6) and titanium tetrachloride (TiCl4). The analysis is applied to a well-known cycle -Recuperated Rankine- and a less common layout -Pre-compression-. The latter is found capable of fully exploiting the interesting features of these non-conventional working fluids, enabling thermal efficiencies up to 2.3% higher than the simple recuperative configuration. Different scenarios for maximum cycle pressure (250-300 bar), turbine inlet temperature (550-700 degrees C) and working fluid composition (10-25% molar fraction of dopant) are considered. The results in this work show that CO2-blends with 15-25%(v) of the cited dopants enable efficiencies well in excess of 50% for minimum cycle temperatures as high as 50 degrees C. To verify this potential gain, the most representative pure sCO(2) cycles have been optimised at two minimum cycle temperatures (32 degrees C and 50 degrees C), proving the superiority of the proposed blended technology in high ambient temperature applications. (C) 2021 The Author(s). Published by Elsevier Ltd.
Thermal efficiency gains enabled by using CO2 mixtures in supercritical power cycles
Di Marcoberardino, G;Di Bona, D;Binotti, M;Manzolini, G
2022-01-01
Abstract
The present paper explores the utilisation of dopants to increase the critical temperature of Carbon Dioxide (sCO(2)) as a solution towards maintaining the high thermal efficiencies of sCO(2) cycles even when ambient temperatures compromise their feasibility. To this end, the impact of adopting CO2-based mixtures on the performance of power blocks representative of Concentrated Solar Power plants is explored, considering two possible dopants: hexafluorobenzene (C6F6) and titanium tetrachloride (TiCl4). The analysis is applied to a well-known cycle -Recuperated Rankine- and a less common layout -Pre-compression-. The latter is found capable of fully exploiting the interesting features of these non-conventional working fluids, enabling thermal efficiencies up to 2.3% higher than the simple recuperative configuration. Different scenarios for maximum cycle pressure (250-300 bar), turbine inlet temperature (550-700 degrees C) and working fluid composition (10-25% molar fraction of dopant) are considered. The results in this work show that CO2-blends with 15-25%(v) of the cited dopants enable efficiencies well in excess of 50% for minimum cycle temperatures as high as 50 degrees C. To verify this potential gain, the most representative pure sCO(2) cycles have been optimised at two minimum cycle temperatures (32 degrees C and 50 degrees C), proving the superiority of the proposed blended technology in high ambient temperature applications. (C) 2021 The Author(s). Published by Elsevier Ltd.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0196890422000486-main.pdf
accesso aperto
:
Publisher’s version
Dimensione
1.49 MB
Formato
Adobe PDF
|
1.49 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.