Hydrogen cyanide (HCN) is a major source of prompt-NOx formation especially in fuel-bound nitrogen systems. To date, there is still a significant disagreement between experimental data and theoretical predic- tions of the rate coefficients of combustion reactions involving HCN as a prompt-NOx precursor. Accurate modeling of NOx formation would greatly benefit from a diagnostic capable of performing high-fidelity measurements of HCN formation/consumption time-histories. In this study, a laser diagnostic is developed for sensitive and selective HCN sensing by probing its most intense absorption feature in the mid-infrared (MIR). The diagnostic is based on difference-frequency generation (DFG) between a CO2 gas laser and an external-cavity quantum cascade laser in a nonlinear orientation-patterned gallium arsenide crystal which results in a DFG laser tunable over 11.56 − 15 μm. HCN measurements were carried out at the peak of the Q-branch of its strong ν2 vibrational band near 14 μm. Pressure dependence of the absorption cross-section was investigated at room temperature over the pressure range of 0.07 − 1.07 bar. Temperature-dependent absorption cross-section measurements were conducted behind reflected shock waves over the temperature range of 850 − 3000 K. The diagnostic was demonstrated in reactive experiments in a shock tube where HCN mole fraction time-histories were measured during the thermal decomposition of isoxazole (C3H3NO) and the first-order rate coefficients of C3H3NO → HCN + CH2CO reaction were determined.
A mid-IR laser diagnostic for HCN detection
Marangoni, Marco;
2023-01-01
Abstract
Hydrogen cyanide (HCN) is a major source of prompt-NOx formation especially in fuel-bound nitrogen systems. To date, there is still a significant disagreement between experimental data and theoretical predic- tions of the rate coefficients of combustion reactions involving HCN as a prompt-NOx precursor. Accurate modeling of NOx formation would greatly benefit from a diagnostic capable of performing high-fidelity measurements of HCN formation/consumption time-histories. In this study, a laser diagnostic is developed for sensitive and selective HCN sensing by probing its most intense absorption feature in the mid-infrared (MIR). The diagnostic is based on difference-frequency generation (DFG) between a CO2 gas laser and an external-cavity quantum cascade laser in a nonlinear orientation-patterned gallium arsenide crystal which results in a DFG laser tunable over 11.56 − 15 μm. HCN measurements were carried out at the peak of the Q-branch of its strong ν2 vibrational band near 14 μm. Pressure dependence of the absorption cross-section was investigated at room temperature over the pressure range of 0.07 − 1.07 bar. Temperature-dependent absorption cross-section measurements were conducted behind reflected shock waves over the temperature range of 850 − 3000 K. The diagnostic was demonstrated in reactive experiments in a shock tube where HCN mole fraction time-histories were measured during the thermal decomposition of isoxazole (C3H3NO) and the first-order rate coefficients of C3H3NO → HCN + CH2CO reaction were determined.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S1540748922004485-main Proc Comb Institute _ 60.pdf
Accesso riservato
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
1.54 MB
Formato
Adobe PDF
|
1.54 MB | Adobe PDF | Visualizza/Apri |
Proc Comb Inst _ accepted _ 60 _ Re Public embargo 24.pdf
Open Access dal 11/11/2024
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
842.84 kB
Formato
Adobe PDF
|
842.84 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.