In this work, a mechanistic dynamic model of continuous flow peracetic acid (PAA) disinfection was developed, calibrated and validated, assuming E. coli as indicator microorganism. The model was conceived as a 1-dimensional dispersion model integrating PAA first order decay and E. coli inactivation rate. Lab-scale batch experiments of PAA decay and E. coli inactivation experiments were performed to calibrate corresponding kinetic models. In each sample, conventional wastewater quality parameters were monitored. A PAA pilot reactor was set up to perform both tracer studies, for dispersion model calibration, and continuous flow disinfection experiments, to validate the integration of hydraulics and kinetics models, under both stationary and dynamic conditions. Linear regression models were calibrated to predict hydrodynamic dispersion, given the flow rate, and PAA decay parameters, given effluent quality and PAA dosage. Successful validation of the PAA disinfection model proved the importance of (i) considering the disinfection process as a dynamic system and (ii) integrating real-time estimation of process disturbances, being the initial E. coli concentration and the impact of effluent quality and PAA dosage on PAA decay kinetics. Importantly, novel inactivation models were proposed, as two different modifications of a literature model for thermal inactivation. These models are suitable for dynamic simulation of Eulerian models and can describe the typical triphasic behavior of inactivation kinetics.

Disinfection efficiency prediction under dynamic conditions: Application to peracetic acid disinfection of wastewater

Foschi, Jacopo;Bianchi, Giulio Francesco;Turolla, Andrea;Antonelli, Manuela
2022-01-01

Abstract

In this work, a mechanistic dynamic model of continuous flow peracetic acid (PAA) disinfection was developed, calibrated and validated, assuming E. coli as indicator microorganism. The model was conceived as a 1-dimensional dispersion model integrating PAA first order decay and E. coli inactivation rate. Lab-scale batch experiments of PAA decay and E. coli inactivation experiments were performed to calibrate corresponding kinetic models. In each sample, conventional wastewater quality parameters were monitored. A PAA pilot reactor was set up to perform both tracer studies, for dispersion model calibration, and continuous flow disinfection experiments, to validate the integration of hydraulics and kinetics models, under both stationary and dynamic conditions. Linear regression models were calibrated to predict hydrodynamic dispersion, given the flow rate, and PAA decay parameters, given effluent quality and PAA dosage. Successful validation of the PAA disinfection model proved the importance of (i) considering the disinfection process as a dynamic system and (ii) integrating real-time estimation of process disturbances, being the initial E. coli concentration and the impact of effluent quality and PAA dosage on PAA decay kinetics. Importantly, novel inactivation models were proposed, as two different modifications of a literature model for thermal inactivation. These models are suitable for dynamic simulation of Eulerian models and can describe the typical triphasic behavior of inactivation kinetics.
2022
Disinfection
Dispersion model
E. coli
Peracetic acid
Pilot-scale validation
Wastewater
File in questo prodotto:
File Dimensione Formato  
2022 Antonelli - Wat Res - PAA disinfection model.pdf

Accesso riservato

Descrizione: Articolo principale
: Publisher’s version
Dimensione 1.29 MB
Formato Adobe PDF
1.29 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1227319
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 2
social impact